Thailand makes about five million tonnes of paper and board a year — corrugating medium and linerboard for the export packaging industry, tissue, printing and writing grades, and specialty papers from bagasse and eucalyptus. Every tonne starts as a slurry of 99.5 % water, and the paper machine's first job is to take most of that water out before the sheet reaches the steam-heated dryers. Gravity and the forming wire remove water to about 2–3 % fibre; from there to the 20 % solids at the end of the forming section and the 40–50 % after the press, the work is done by vacuum. A 200 t/d packaging machine pulls 30,000–60,000 m³/h of air through its sheet, felts and rolls, at vacuum levels from 100 to 650 mbar, continuously, in air that is saturated with warm water and carries fibre, filler and chemicals.

1. The vacuum positions

Along the machine, in order:

Position What it does Vacuum level (gauge) Air flow
Flat (low-vac) boxes Dewater the sheet on the wire from 3 to 6–8 % solids −100 to −250 mbar Very high: 200–400 m³/min per metre of width
High-vac (wet) boxes Continue dewatering to 12–18 % −300 to −500 mbar High
Suction couch roll Final wire dewatering to 18–22 %, holds sheet to the wire at the turn −500 to −650 mbar Medium
Pick-up roll / transfer Lifts the sheet from wire to felt −400 to −600 mbar Medium
Suction press rolls Dewater sheet and felt in the press nip −500 to −650 mbar Medium
Uhle (felt conditioning) boxes Remove water and contaminants from press felts −300 to −500 mbar Medium: 10–30 m³/min per metre
Felt and wire suction rolls, trim squirts, tail threading Various −200 to −500 mbar Low

The air flows are what make a paper machine's vacuum system large: a 5 m wide machine may need 25,000 m³/h at the low-vac boxes alone. The vacuum levels are what make it a liquid ring system: nothing in the flow range tolerates saturated, fibre-laden air at −650 mbar (350 mbar absolute) except a water-ring machine — and the paper machine's own white water is the ring liquid.

Why does a paper machine use liquid ring pumps rather than blowers?

Because the suction couch and press rolls need −500 to −650 mbar, which is beyond any blower's reach, and because the gas is water. Side channel and Roots blowers stop at −400 to −490 mbar; centrifugal blowers at −200. A liquid ring pump reaches −650 mbar with ease, is indifferent to the water, fibre and filler in the air (they pass through and leave with the seal water), runs cool (the compression heat goes into the water, so the air leaves at 35–40 °C regardless of the machine's 50 °C hood), and has one moving part. Paper machines have run on liquid ring pumps since the 1920s. The one place blowers have entered is the low-vac boxes, where −100 to −250 mbar is enough and the air flow is enormous: a turbo blower (a high-speed centrifugal machine) uses less energy than a liquid ring pump there, and modern machines pair turbo blowers on the flat boxes with liquid ring pumps on everything deeper.

2. Sizing by position

Paper machine vacuum sizing is empirical and well documented; the air-flow factors below (per metre of machine width, at the stated vacuum) are representative for a packaging grade at moderate speed:

Position Air flow per metre width Vacuum
Flat boxes (3–5 boxes) 250 m³/min −150 mbar
High-vac boxes (2–3) 120 m³/min −400 mbar
Suction couch 60 m³/min −600 mbar
Pick-up 40 m³/min −500 mbar
Suction press 40 m³/min −600 mbar
Uhle boxes (3 felts) 60 m³/min −400 mbar

For a 4.5 m wide, 250 t/d linerboard machine:

  • Flat boxes: 4.5 × 250 = 1,125 m³/min ≈ 67,000 m³/h at −150 mbar
  • High-vac boxes: 540 m³/min ≈ 32,000 m³/h at −400 mbar
  • Couch: 270 m³/min ≈ 16,000 m³/h at −600 mbar
  • Pick-up + press: 360 m³/min ≈ 22,000 m³/h at −500/−600 mbar
  • Uhle boxes: 270 m³/min ≈ 16,000 m³/h at −400 mbar

A total of about 150,000 m³/h of inlet air — served by a vacuum plant of eight to twelve large liquid ring pumps, each dedicated to one or two positions at a matched vacuum level (a pump on the couch at −600 mbar must not share a header with the flat boxes at −150 — the deeper position would pull the shallow one down and waste power). Pumps are selected from the manufacturer's curve at the position's vacuum level and the seal water temperature: a liquid ring pump's capacity at −600 mbar with 35 °C white water is perhaps 55–60 % of its nominal.

Dr.Vakuum's LS Series covers the mid-size positions on tissue and packaging machines: an LS520-400 (2,600 m³/h nominal, 55 kW) delivers about 1,500 m³/h at −600 mbar on warm water — three of them on a 2.5 m tissue machine's couch and press; an LS780-1100 on the larger positions. Large newsprint and board machines use cone-type liquid ring pumps of 10,000–30,000 m³/h, which we size and supply per project.

3. Separators, white water and seal water

Each vacuum position's air arrives at a water separator — a vertical vessel where the air slows, the entrained water (tonnes per hour from the couch) falls to a seal pit or barometric leg, and the air goes on to the pump. Separators are sized for 1–2 m/s air velocity and fitted with a demister; the water they collect is white water that goes back to the machine's wire pit. A pump that receives the separator's water directly is a pump sized for liquid, not air.

The seal water for the liquid ring pumps:

  • Fresh water once-through: simplest, but 5–10 m³/h per large pump — on a 12-pump plant, a river.
  • Recirculated with cooling: a seal water tank, plate heat exchanger against mill cooling water, 10–20 % bleed. Standard on modern machines.
  • White water as seal water: the pump's own discharge water, clarified in the separator, recirculated. Saves fresh water entirely; the pump must tolerate fibre and filler in its ring (the LS Series does, with a strainer at 1–2 mm), and the water runs warm (40–45 °C), costing capacity — the trade-off every mill makes differently.

Materials: stainless steel impellers and port plates as standard on paper machine pumps — white water is slightly acidic to neutral, with chlorides from the furnish and alum from the wet-end chemistry.

4. Energy

A paper machine's vacuum system is typically 8–12 % of the machine's electrical load — 1–2 MW on a 250 t/d machine. Reductions that pay:

  • Match each pump to its position's vacuum: a pump pulling −600 mbar on a position that needs −400 wastes a third of its power. Separate headers, throttle valves replaced by VSDs.
  • Variable-speed drives on the flat and uhle box pumps: the air flow a felt needs changes as it ages; a VSD follows it.
  • Turbo blowers on the flat boxes: 30–40 % less energy than liquid ring at −150 mbar; the Dr.Vakuum CB Series high-flow centrifugal machines serve the shallowest positions on smaller machines.
  • Seal water temperature: every 5 °C cooler is 8–10 % more capacity at deep vacuum; a cooling tower on the seal water loop is usually the cheapest kilowatt on the machine.
  • Leaks: a wire or felt that no longer seals the box face lets air through that the pump then compresses for nothing; box covers and felt condition are a vacuum-energy item.

5. Worked machines

Machine Width Positions Dr.Vakuum answer
Tissue, 2.7 m, 60 t/d 2.7 m Forming roll, suction press, uhle 2 × LS520-400 (press, −600), 1 × LS410-320 (uhle, −400), 1 × LS275-220 (forming roll)
Packaging, 3.5 m, 150 t/d 3.5 m Flat, high-vac, couch, press, uhle Flat boxes: CB turbo blowers; high-vac and uhle: 3 × LS520-400; couch and press: 2 × LS780-1100
Specialty, 1.8 m, 20 t/d 1.8 m Boxes, couch, press, uhle LS275-220 ×2, LS410-320 ×1, LT250-200 on the couch
Linerboard, 4.5 m, 250 t/d 4.5 m Full Cone-type liquid ring pumps per project; LS Series on uhle and pick-up positions

Recommended Dr.Vakuum machines

Liquid ring single-stage (LS Series), stainless, white-water capable — mid-size positions on tissue, specialty and packaging machines: LS275-220 (650 m³/h), LS410-320 (1,400 m³/h), LS520-400 (2,600 m³/h), LS780-1100.

Two-stage liquid ring (LT Series) — deep positions (couch at −650 mbar) with warm seal water: LT250-200, LT380-320.

Centrifugal blowers (CB Series) — flat boxes at −100 to −200 mbar on smaller machines: CB125A, CB150A.

The sheet goes from here to the dryers; the finished reel goes to converting, where vacuum appears again on printing presses and sheet feeders.

Machine to vacuum plant. Send us the machine width, speed, grade and the position list with vacuum levels, and we will return a pump schedule per position with seal water and power. Talk to an engineer.