Dr.Vakuum
Все применения

Poultry processing: evisceration, giblet and offal vacuum systems

7 мин чтения

Thailand processes well over a billion broilers a year for export and the domestic market, in plants running 6,000 to 15,000 birds an hour per line. Behind the evisceration line, a vacuum system does work that was once done by hand with a spoon: it draws the lungs and kidneys out of the carcass cavity, carries giblets and inedible viscera away in pipes, and keeps the floor from being a river. It is one of the hardest vacuum duties in the food industry — not deep, but relentlessly wet and full of organic debris — and the pumps that survive it are liquid ring machines with a well-designed separator in front of them.

1. The duties on the line

Lung and kidney removal. After the automatic eviscerator, a lung gun — a hand-held or automatic nozzle with a serrated tip — is pushed into the cavity and vacuum strips the lungs from the ribcage and the kidneys from the pelvic bone. Each gun draws 60–100 m³/h of free air at −400 to −500 mbar when open to atmosphere, less when sealed in a cavity. A line has 2–6 lung guns (automatic machines have one per shackle station, several in parallel).

Vacuum transport. Giblets (heart, liver, gizzard), crops, heads, feet and inedible viscera are sucked into transport lines of 50–100 mm from the inspection station to the giblet-processing room or the offal collection tank, 30–100 m away. Each transport system needs 300–800 m³/h at −300 to −450 mbar depending on line length and the material (whole viscera packs are the hardest).

Cleaning and drain pick-up. Floor suction points and the cleaning nozzles for the inspection troughs.

In a 13,500 bird/h plant the total installed vacuum flow is typically 1,500–3,000 m³/h at −400 mbar, served by a central system in a plant room with two to four pumps.

Why does nothing but liquid ring last on this duty?

Because the gas arriving at the pump is 10–30 % liquid by volume on a bad minute: water from the washers, blood, bile when a gall bladder breaks, tissue fragments that passed the separator screen, and proteinaceous foam. An oil-sealed pump's oil is destroyed in hours; a dry vane or claw pump corrodes and binds within weeks; a side channel blower's impeller fills with debris. A liquid ring pump is designed to be full of water — the slugs pass through it, the debris is washed out with the seal water, the acidic condensate is diluted, and the pump neither heats nor stalls. It is also inherently cool and quiet. The engineering effort goes into the separator ahead of it and the seal water loop around it, not into keeping the gas dry.

2. Sizing by nozzle and simultaneity

Plant designers size from the equipment list, with a simultaneity factor because not every gun is open at once:

Consumer Free air per unit Working vacuum Simultaneity
Lung gun, manual 60–80 m³/h −450 mbar 0.6
Automatic lung remover, per head 80–100 m³/h −500 mbar 0.8
Giblet transport line, 75 mm, 60 m 400–600 m³/h −350 mbar 1.0 while running
Crop transport line, 50 mm 250–350 m³/h −350 mbar 1.0
Viscera / inedible line, 100 mm 600–900 m³/h −450 mbar 1.0
Floor suction point 100–150 m³/h −300 mbar 0.2

A 13,500 bird/h line: 4 manual lung guns (4 × 70 × 0.6 = 170), one automatic lung remover with 4 heads (320), giblet line (500), crop line (300), inedible line (750), 6 floor points (6 × 120 × 0.2 = 145) → ~2,200 m³/h of free air at −400 to −500 mbar, at the plant.

The pump must deliver that at the working vacuum, read from the hot-seal-water curve. A liquid ring pump's curve falls from its nominal figure to about 60–70 % at −450 mbar (550 mbar absolute) with 30 °C seal water, so the installed nominal capacity is ~3,300 m³/h: three LS275-220 at 650 m³/h plus one LS410-320 at 1,400 m³/h, with the LS410 as the duty transport pump and the smaller units on the guns and floor — or two LS410-320 and one LS275-220 for a simpler spares list. A fourth pump as standby: the kill line cannot stop.

Pipework for the gun side at 5–8 m/s and the transport lines at 25–35 m/s (to keep viscera moving), in stainless, with long-radius bends and inspection ports at every bend. Pressure drop on a 60 m transport line with product is 100–150 mbar; the plant set point is therefore −500 to −550 mbar to deliver −400 at the far nozzle.

3. The separator is the system

Between the lines and the pumps sits the central separator (or one per transport line): a stainless vessel of 1–3 m³ where the air slows below 1 m/s, the liquid and solids drop out, a perforated screen (6–10 mm) holds back tissue, and a demister catches the fine mist. Design points from plants that work:

  • Tangential inlet well above the liquid level, so the incoming jet does not re-entrain what has settled.
  • Continuous discharge: a screw or a pump-out that moves the collected material to the by-product room without breaking the vacuum (a rotary valve rated for wet solids, or a dual-vessel lock). A separator that must be emptied by stopping the line is a separator that gets emptied too late.
  • Level control with a high-level alarm and a pump trip — the one interlock that saves the pumps.
  • CIP spray balls inside, on a timer, since the vessel is a biological hazard within hours.
  • Secondary knock-out pot at each pump inlet for what the central separator misses; sight glass, drain, strainer basket.

4. Seal water in a poultry plant

Potable water is costly and the plant uses a great deal of it; the vacuum pumps run on a recirculated seal water loop with a plate heat exchanger against the plant's chilled water or cooling tower, and a 10–20 % bleed and make-up. The loop picks up organic load from the gas, so:

  • A separator tank with a skimmer (fat floats) and a bottom drain (solids sink), cleaned daily.
  • Chlorine dosing to 2–5 ppm, or peracetic acid, to keep the loop from becoming a culture.
  • Stainless steel pumps throughout; blood and chlorinated water corrode cast iron together.
  • Seal water temperature held at 25–30 °C — every 5 °C warmer costs 10 % of the pump's capacity at the working vacuum.

5. Hygiene and the plant room

  • Pumps in a dedicated plant room next to the by-product area, on plinths, drained floor, hose-down construction.
  • Exhaust from the separators and pumps to outside through an odour filter; the exhaust is biologically loaded air.
  • Vacuum lines sloping to the separators with no pockets; inspection and CIP ports.
  • Nozzles and guns in stainless, with quick-release couplings, on the plant's CIP cycle.
  • Zones: the inedible transport system is physically separate from the giblet (edible) system — separate separator, separate pump — to satisfy export audits.

6. Worked plants

Plant Birds/h Vacuum flow at −450 mbar Dr.Vakuum answer
Small domestic processor 3,000 ~500 m³/h 2 × LM270-155 (375 m³/h each), one standby
Mid-size export line 7,500 ~1,300 m³/h 2 × LS275-220 + 1 × LM270-155
Large export plant, one line 13,500 ~2,200 m³/h 2 × LS410-320 + 1 × LS275-220, +1 standby
Two-line complex 27,000 ~4,500 m³/h 3 × LS520-400 (2,600 m³/h each)

Recommended Dr.Vakuum machines

Liquid ring, single-stage (LM and LS Series), stainless — the poultry plant vacuum pump; 33–40 mbar ultimate is irrelevant, the tolerance of liquid and debris is everything.

Model Nominal, 50 Hz Motor Role
LM200-065 105 m³/h 3 kW Single lung-gun station, small plant
LM270-155 375 m³/h 11 kW Gun manifold, crop line
LS275-220 650 m³/h 15 kW Giblet or crop transport
LS410-320 1,400 m³/h 37 kW Inedible transport, central duty
LS520-400 2,600 m³/h 55 kW Large central systems

The marination that follows in the further-processing plant is an oil-free, dry-pump duty — see Vacuum tumbling and marination.

Line to plant room. Send us the line speed, the equipment list with nozzle counts, and the transport line routes, and we will return the diversified flow, the pump schedule and the separator sizing. Talk to an engineer.