Vacuum-assisted aluminium die casting: evacuating the die in 100 milliseconds
Thailand's die-casting industry supplies the aluminium housings, brackets, gearbox cases and structural parts for the vehicles it builds, and the shift to electric vehicles — battery housings, motor housings, large thin-walled structural castings — has made vacuum-assisted die casting the norm rather than the exception on new cells. The reason is porosity. A conventional high-pressure die-casting (HPDC) shot traps the air that was in the cavity and the shot sleeve as fine gas porosity, which makes the casting leak, weakens it, and — critically — blisters when it is heat-treated or welded. Removing that air before the shot gives a casting that can be T6-treated, welded and used structurally.
1. What has to happen, and how fast
The HPDC cycle: the die closes; molten aluminium is ladled into the horizontal shot sleeve; the plunger advances slowly to close the pour hole and push the metal toward the gate; then it accelerates and fills the cavity in 20–60 milliseconds; then intensifies the pressure to feed shrinkage. Vacuum is applied from the moment the plunger passes the pour hole to the moment the metal reaches the vacuum valve at the far end of the cavity — a window of 0.3 to 1 second, during which the cavity (0.5–5 L) and the shot sleeve air space (2–10 L) must drop from atmosphere to 50–100 mbar.
No vacuum pump evacuates 10 L to 100 mbar in half a second: that would be 10 L × ln(10) / 0.5 s ≈ 46 L/s ≈ 170 m³/h at the die, through a vacuum channel a few millimetres deep. Instead the system uses a vacuum tank — a reservoir of 100–500 L held at 5–20 mbar — and a fast valve. Opening the valve lets the die's air expand into the tank; the pressure equalises in tens of milliseconds, limited only by the channel's conductance. The pump's job is to pull the tank back down to its set point in the 40–90 seconds before the next shot.
Why is the tank-to-die volume ratio the number that matters?
Because the pressure the die reaches is set by sharing the die's air with the tank's volume, not by the pump. If the tank at pressure p_t and volume V_t is connected to the die at atmospheric pressure p_0 and volume V_d, the equalised pressure is approximately
p = (p_t × V_t + p_0 × V_d) / (V_t + V_d)
A 10 L die volume into a 200 L tank at 10 mbar: p ≈ (10 × 200 + 1,013 × 10) / 210 ≈ 58 mbar — a good result. Into a 50 L tank at 10 mbar: p ≈ (500 + 10,130) / 60 ≈ 177 mbar — too high for a structural casting. The rule from the machine builders is a tank of 20–50 times the evacuated die volume, held at 10–20 mbar. The pump only has to be able to restore the tank between shots, which is a far easier duty.
2. Sizing the pump for tank recovery
After the shot, the tank sits at the equalised pressure (~60 mbar in the example) and must return to 10 mbar before the next shot, in the cycle time less the vacuum-on window — say 50 seconds on a 60-second cycle:
S = (0.2 m³ / 50 s) × ln(60 / 10) × 3,600 = 0.004 × 1.79 × 3,600 ≈ 26 m³/h
Add the leakage through the die's vacuum channel and the shot-sleeve seal during the vacuum window (significant — the plunger tip seal against a hot sleeve is not perfect), and the air that entered through the pour hole, and the practical figure is 50–100 m³/h for a single cell with a 200–300 L tank. Machine builders fit 60–160 m³/h pumps; a cell casting large structural parts with two vacuum valves and a 500 L tank runs 160–300 m³/h.
The set point of 10–20 mbar is comfortably above a single-stage oil-sealed pump's 0.5 mbar ultimate, so a V63 or V140 runs on its plateau. It is below a dry vane pump's 90 mbar ultimate, which rules the DRV out for the tank duty — unless the tank set point is 100 mbar and the tank ratio is correspondingly larger (some cells casting non-structural parts run this way, with a DRV100 and a 500 L tank, accepting a cavity pressure of 150–200 mbar). Dry claw (CL300, 50 mbar) suits a 20–30 mbar tank.
3. What the pump breathes
The air drawn from the die carries what was in the die:
- Release agent (die lubricant) spray residue — water-based emulsions of wax and silicone sprayed onto the die every cycle; the vacuum pulls the mist and the steam from it.
- Plunger lubricant — oil or wax beads in the shot sleeve, which burn and smoke on contact with the metal.
- Aluminium oxide and dross dust, and occasionally metal splash if the vacuum valve closes late.
- Hot, humid air — die surfaces at 200–300 °C.
Protection:
- The vacuum valve itself (mechanical, triggered by the metal front, or hydraulic, timed from the plunger position) is the first barrier against metal. A chill block (a corrugated steel vent that freezes the metal front) is the backup.
- A filter at the die — a replaceable metal-mesh or sintered element in the vacuum line — stops splash and dross.
- A knock-out pot / separator at the tank inlet with a drain for the release-agent water and wax; cleaned daily.
- Inlet filter (5–10 µm) at the pump, differential gauge.
- Oil-sealed pump: gas ballast open (the release agent is mostly water), oil change by condition — wax in the oil is visible as a cloudy film. Exhaust mist separator.
The tank itself is a settling vessel: the mist drops out in it, and a tank with a drain and an inspection hatch, cleaned weekly, protects the pump more than any filter.
4. Integration with the cell
- Vacuum-on signal from the shot controller at plunger position (pour hole closed); vacuum-off from the vacuum valve or a time delay; shot inhibit if the tank is above its set point — the single most useful interlock, since a shot made at poor vacuum is scrap that looks fine until X-ray or heat treatment.
- Tank pressure logging per shot for process capability (structural-casting customers ask for it).
- Pump control: continuous running with a vacuum switch on the tank, or a VSD that slows between shots; stop-start every minute shortens contactor and motor life.
- Standby: a central vacuum ring to several cells with a duplex pump set, each cell keeping its own tank and valve, is common on new halls — the pump room is quieter and the cells share spares.
5. Worked cells
| Cell | Die + sleeve volume | Tank | Set point | Recovery pump | Dr.Vakuum answer |
|---|---|---|---|---|---|
| 400 t, small housings | 3 L | 100 L | 20 mbar | ~25 m³/h | V40 |
| 800 t, gearbox cases | 8 L | 250 L | 10 mbar | ~60 m³/h | V63 or V100 |
| 1,600 t, structural, two valves | 15 L | 500 L | 10 mbar | ~130 m³/h | V140 |
| 3,500 t, EV battery housing | 40 L | 1,500 L | 5 mbar | ~300 m³/h | V301, or V630 for a 45 s cycle |
| 6-cell hall, central | — | per cell | 10 mbar ring | ~400 m³/h | 2 × V301 duplex |
| Non-structural, dry pump | 5 L | 500 L | 100 mbar | ~50 m³/h | DRV60 |
Recommended Dr.Vakuum machines
Single-stage oil-sealed vane (V Series) — tank recovery to 5–20 mbar, gas ballast for the release agent: V40, V63, V100, V140, V301, V630.
Dry claw (CL Series) — oil-free cells at 20–50 mbar tank set point: CL300.
Dry rotary vane (DRV Series) — non-structural cells at a 100 mbar set point with a large tank: DRV60, DRV100.
Castings that still show porosity after vacuum die casting are sealed by vacuum impregnation; the end-of-line leak test is what finds them.
Cell to tank and pump. Tell us the die and sleeve volume, the cycle time and the cavity pressure the customer requires, and we will size the tank ratio and the recovery pump. Talk to an engineer.