Dr.Vakuum
Alle Anwendungen

Beverage deaeration and beer bottling vacuum: oxygen is the enemy

7 Min. Lesezeit

Thailand's breweries, soft-drink bottlers and juice packers run some of the fastest filling lines in Asia — 40,000 to 80,000 containers an hour — and all of them are fighting the same molecule. Oxygen in a beer at more than about 50 parts per billion makes it taste of cardboard within months; oxygen in a juice browns it and destroys vitamin C; oxygen in a carbonated soft drink causes foaming and short fills. Vacuum is used twice to keep it out: in deaerating the water that goes into the product, and in evacuating the container before the product goes in.

1. Water deaeration

Brewing liquor for high-gravity dilution, blending water for soft drinks, and the water for reconstituted juice all arrive saturated with air — about 8–10 mg/L (ppm) of dissolved oxygen at Thai tap-water temperatures. The target after deaeration is below 20–50 ppb for beer, below 0.5 ppm for soft drinks.

Vacuum deaeration works by Henry's law: the dissolved gas content is proportional to the partial pressure of that gas above the liquid. Spray or film the water into a column held at 40–80 mbar absolute — just above the water's own vapour pressure at its temperature (23 mbar at 20 °C, 32 at 25 °C) — and the oxygen partial pressure above the water falls to almost nothing; the dissolved oxygen leaves in seconds. A CO₂ stripping gas sparged into the column improves it further (the CO₂ scrubs the last oxygen and ends up as harmless carbonation); two-stage columns reach single-digit ppb.

The pump duty:

  • Gas load: the air stripped from the water — 10 m³/h of water carries about 0.2 Nm³/h of dissolved air — plus the stripping CO₂ if used (0.5–2 Nm³/h), plus air in-leakage through the column seals and the feed pump gland (1–5 Nm³/h on a tight system), plus water vapour saturated at the column temperature, which at 60 mbar and 25 °C is more than half the gas by volume.
  • For a 30 m³/h brewing-water deaerator at 60 mbar, 25 °C: about 4 Nm³/h of non-condensables → at 60 mbar, with vapour, roughly 150 m³/h of actual volume.
  • Pump-down of the column and its receiver at start-up is a minor requirement by comparison.

A liquid ring pump is the standard choice — the gas is saturated, the pump runs cool, and its seal water can be the deaerated water itself in a closed loop on the hygienic side. An LM200-065 (105 m³/h) with chilled seal water, or an LM230-120 (230 m³/h) where the column runs at 40 mbar and the seal water is warm.

Why does seal water temperature decide whether the deaerator works?

Because the column pressure must sit just above the water's vapour pressure to strip oxygen without boiling the water away — 40–60 mbar for 20–30 °C water — and a liquid ring pump's lowest attainable pressure is set by the vapour pressure of its seal water. With 32 °C seal water (48 mbar vapour pressure) the pump cannot hold 50 mbar; with 15 °C seal water (17 mbar) it holds 40 mbar with its capacity intact. Brewers already have chilled water; run the seal water loop through a plate exchanger against it. Where that is impossible, an air ejector ahead of the liquid ring pump, or a dry pump, is the answer.

2. Container pre-evacuation at the filler

A beer or carbonated soft drink filler fills bottles or cans under counter-pressure. Before the product enters, the container is full of air; left there, it ends up as oxygen in the headspace and the beer. Fillers use one of two methods:

  • CO₂ flushing alone: purging the container with CO₂ pushes most of the air out, at a CO₂ cost of several container volumes.
  • Double pre-evacuation: the filling valve evacuates the container to 100–200 mbar absolute (−800 to −900 mbar gauge), fills it with CO₂, evacuates again, fills with CO₂ again, then pressurises and fills with product. Two evacuations reduce the residual air to under 2–3 % — the oxygen pickup falls to 10–20 ppb — and CO₂ consumption falls by more than half compared with flushing alone. Can fillers typically single-evacuate; glass fillers for premium beer double-evacuate.

The pump duty is a high-cycle small-volume one. A 40,000 bph glass filler with 120 valves, 500 mL bottles, double pre-evacuation to 150 mbar:

  • Air removed per evacuation: 0.5 L × (1,013 − 150)/1,013 ≈ 0.43 L
  • Two per bottle → 0.85 L; times 40,000/h → 34 m³/h of free air, as short pulses through a vacuum ring channel on the filler
  • Plus the ring channel's own leakage through 120 valve seals, plus the CO₂ from the second evacuation (which is CO₂, not air — the pump exhausts it)

Filler manufacturers specify a pump of 60–120 m³/h at 150 mbar for such a machine, with a vacuum receiver on the ring channel to smooth the pulses, and a pump that tolerates beer foam and CO₂. Beer and product splash reach the vacuum channel every time a bottle bursts in the filler, and the gas is saturated and sticky.

Two pump choices serve this:

  • Liquid ring (LM Series): the traditional filler pump, with a separator and a CIP-able seal water loop; tolerates foam, beer and glass fragments. The 33 mbar ultimate is deep enough for 150 mbar at the valve with the ring channel losses. LM145-080 (80 m³/h) or LM200-065 (105 m³/h).
  • Dry claw (CL Series): where the plant wants no seal water and no oil near the filler; 150 mbar ultimate is marginal for a 150 mbar valve set point, so the CL300 (50 mbar) is the model for double pre-evacuation; a knock-out pot with a float valve protects it from beer.

Oil-sealed pumps are generally not used on fillers: a filler is the most hygienically sensitive machine in the hall, and the vacuum channel is open to the bottle mouth.

3. Other vacuum points in a filling hall

  • Juice and syrup deaerators: spray deaeration at 60–100 mbar before pasteurisation, for colour and foam control — the vapour load is higher (warmer product), the gas carries sugar mist; liquid ring with a knock-out pot, LM200-065 to LM270-155.
  • Labelling machines: vacuum drums for label handling, 150–300 mbar below atmosphere, 30–60 m³/h, dry — a DRV40 or a side channel blower.
  • Vacuum conveyors and closure handling: cap and preform feeders, side channel blowers.
  • CIP return: vacuum-assisted drain recovery on some systems, liquid ring.

4. Hygiene, CIP and the plant room

  • Pumps serving fillers and deaerators are outside the filling hall, in a plant room, with inlet lines sloping back to a separator that can be CIP'd with the filler circuit.
  • Stainless steel liquid ring pumps on beer and juice (the condensate is acidic — carbonic acid and fruit acids).
  • Seal water for liquid ring pumps on the hygienic side from treated water with a chlorine or PAA residual, closed loop with bleed.
  • Exhaust of filler vacuum pumps is CO₂-rich; vent outside, not into the hall, and monitor CO₂ in the plant room.
  • Dry pumps: exhaust silencers and a drain leg for condensate.

5. A worked filling hall

A brewery with a 40,000 bph glass line and a 60,000 cph can line, plus a 50 m³/h dilution-water deaerator.

Duty Pressure Flow at duty Dr.Vakuum answer
Glass filler, double pre-evacuation 150 mbar ~90 m³/h LM200-065, stainless, 200 L receiver, separator
Can filler, single pre-evacuation 200 mbar ~60 m³/h LM145-080, stainless, receiver
Dilution-water deaerator, 50 m³/h 50 mbar, CO₂ stripping ~250 m³/h LM230-120 with chilled seal water
Labellers (2) 300 mbar below atm 2 × 40 m³/h 2 × DRV40

Recommended Dr.Vakuum machines

Liquid ring monobloc (LM Series), stainless — fillers and deaerators: LM145-080 (80 m³/h), LM200-065 (105 m³/h), LM230-120 (230 m³/h), LM270-155 (375 m³/h).

Dry claw (CL Series) — fillers without seal water: CL300.

Dry rotary vane (DRV Series) — labellers and dry handling: DRV40, DRV60.

The same deaeration physics applied to juices and purées before canning is in Vacuum in canning.

Line to pump. Tell us the filler speed, container size and whether it single- or double-evacuates, and the deaerator flow and pressure, and we will size the pumps with their receivers and seal water loops. Talk to an engineer.