Dr.Vakuum
การประยุกต์ใช้งานทั้งหมด

Fish meal, pet food and aquafeed: vacuum coating of fat and flavour

อ่าน 7 นาที

Thailand is the world's largest shrimp-feed producer and a major maker of fish feed, pet food and livestock feed, and the step that decides whether a high-energy pellet delivers its fat without leaking it into the bag is the vacuum coater. An extruded, dried pellet is 30–40 % porous. Spray fat onto it at atmosphere and the fat sits on the surface — 10–12 % is about the maximum before the pellets are greasy and the fines are sticky. Spray it under vacuum and release the vacuum, and atmospheric pressure pushes the fat into the pores: 25–40 % total fat in a salmon or marine shrimp feed, palatants and probiotics carried deep into a kibble where they survive handling.

1. The cycle and the physics

A batch of warm pellets (50–80 °C from the dryer) is loaded into a sealed mixer or drum — 1,000 to 4,000 kg per batch on a feed mill line. Then:

  1. Evacuate the coater to 100–300 mbar absolute in 30–90 seconds. The air in the pellet pores expands and leaves.
  2. Spray the fat (heated to 50–60 °C so it flows), and any liquid additives, onto the tumbling pellets under vacuum, 20–60 seconds. The fat coats the surface; the pores are still nearly empty.
  3. Release the vacuum slowly (30–120 seconds) through a filter. As pressure rises, the atmosphere drives the surface fat into the pores — the slower the release, the deeper the penetration and the fewer the broken pellets.
  4. Discharge; next batch. Total cycle 3–6 minutes; a 2-tonne coater does 20–30 t/h.

The vacuum depth sets how much of the pore volume is available: at 200 mbar absolute, 80 % of the air is gone and 80 % of the pore volume can take fat. Deeper than about 100 mbar gains little and starts to pull moisture and volatile flavour compounds out of the pellet. 150–250 mbar is where most coaters are set.

Why must the release be slow if the vacuum is what matters?

Because the pellet is a porous solid with a fat film on it, and the film is pushed in by the difference between the rising chamber pressure and the pressure still inside the pore. A sudden release drives the fat in so fast that the pore's remaining air is compressed and fights back, the fat stays shallow, and the pressure shock fractures the weaker pellets into fines — fines that then soak up fat and form a greasy cake on the coater wall. A controlled release over a minute or two lets the air in the pore dissolve into the fat and escape ahead of it. The vacuum pump sets the evacuation time; a control valve and a filter on the inlet air set the release. Both matter; the second is the one plants get wrong.

2. Sizing the pump

The coater is a batch chamber: pump-down time sizes it. A 2-tonne coater has a vessel volume of about 5 m³, of which the pellets occupy roughly half (bulk density 600–700 kg/m³ → 3 m³ of pellets, but the inter-pellet voids are also air, so the free air volume is closer to 4 m³). To 200 mbar in 60 seconds:

S_eff = (4 / 60 s) × ln(1,013 / 200) × 3,600 = 0.067 × 1.62 × 3,600 ≈ 390 m³/h

Coater manufacturers fit 300–600 m³/h for a 2-tonne machine, and proportionally for others:

Coater batch Free air volume Pump-down to 200 mbar in 60 s Dr.Vakuum answer
500 kg (pilot, pet treats) 1 m³ ~100 m³/h DRV100
1,000 kg 2 m³ ~200 m³/h DRV250 or CL251
2,000 kg 4 m³ ~400 m³/h DRV400, or RBV065 + filter
4,000 kg 8 m³ ~800 m³/h RBV100 (347–801 m³/h) with a receiver

The target pressure of 200 mbar is far above the ultimate of every candidate (dry vane 90 mbar, claw 150 mbar), so the pump-down formula is accurate and the pumps run on their plateau. A Roots vacuum blower (RBV Series, −490 mbar maximum, i.e. about 520 mbar absolute) does not reach 200 mbar alone — but the first 500 mbar of the pump-down is where most of the air volume is, and a large RBV doing the bulk work with a smaller dry pump finishing to 200 mbar is a common and economical two-machine layout on 3–4 tonne coaters.

A vacuum receiver of 2–5 m³ held at 100 mbar between cycles lets a smaller pump run continuously and dump the coater in seconds — the coater is "pumped down" by opening a large valve to the receiver. For a line with two coaters alternating, one receiver and one pump serve both.

3. The gas: hot, oily, dusty

Every pump-down draws from the coater:

  • Pellet fines and dust — the pellets are abraded as they tumble; 0.5–2 % fines, 50–500 µm, high in fat and protein, hygroscopic.
  • Fat mist — the spray is atomised fat at 55 °C in a chamber being evacuated; some of it is airborne when the valve opens.
  • Water vapour — warm pellets at 60 °C and 8–10 % moisture in a 200 mbar chamber lose a little moisture each cycle (the vapour pressure at 60 °C is 200 mbar — right at the set point, another reason not to go deeper).
  • Steam flash on coaters loaded directly from the dryer.

Protection, in order from the coater: a cyclone (removes the bulk of fines, returns them to the process), a cartridge filter rated 10–25 µm with a differential gauge and reverse-pulse cleaning on large systems, a knock-out pot with a heated jacket (so condensed fat does not set in it) and a drain, then the pump. Dry vane and claw pumps need all three; a Roots vacuum blower needs the cyclone and filter. Fat that reaches a dry vane pump glazes the vanes; fat that reaches a claw pump bakes onto the rotors at the discharge temperature. The filter and knock-out are not optional.

4. Oil-free, and why

The coater is a food-contact vessel (feed is food, under Thai and EU feed-hygiene regulation) and the vacuum connection is open to the product. Mineral oil from an oil-sealed pump back-streaming into a coater is a contamination event; the plant's GMP+ or FAMI-QS auditor will ask how it is prevented. Dry pumps — dry vane (DRV), dry claw (CL) or Roots blowers (RBV) — remove the question, and their ultimate pressures (90, 150 and ~520 mbar) match a 150–250 mbar duty naturally. Liquid ring pumps are used on some fish-meal plant coaters (the duty is wet and the gas smells), but the seal water becomes an oily emulsion that must be managed.

5. Fish meal plants

Fish meal and fish oil plants use vacuum in two more places: vacuum evaporators concentrating stickwater (the press liquor) from 6 % to 30–40 % solids at 60–150 mbar — a classic multi-effect evaporator duty with a liquid ring pump on the condenser (LS275-220 class, as in sugar evaporators) — and vacuum deodorisation/polishing of fish oil, a smaller version of the palm oil deodoriser duty at 5–20 mbar with a booster and liquid ring set. Both are wet, smelly and corrosive (volatile amines); stainless liquid ring pumps with closed-loop seal water and a scrubber on the exhaust.

6. A worked feed mill

A shrimp-feed mill with two 2-tonne vacuum coaters alternating at 4 minute cycles (30 t/h), coating to 12 % fish oil plus liquid attractant, set point 200 mbar, release over 90 seconds.

  • Free air per coater ~4 m³; two coaters, one pumping down while the other sprays and releases → one pump-down per 2 minutes.
  • Receiver 4 m³ held at 120 mbar; the coater dumps into it through a DN150 valve in 15 seconds, reaching ~250 mbar, and the pump finishes the last 50 mbar while recovering the receiver.
  • Pump: continuous duty of (4 m³ × 0.8 atmospheres) per 2 minutes ≈ 100 m³/h of free air at 120 mbar — one DRV140 or a CL150 does it, where without the receiver each coater would have needed a 400 m³/h pump.
  • Cyclone and cartridge filter per coater, jacketed knock-out pot at the pump, filtered and valve-controlled release air.

Recommended Dr.Vakuum machines

Dry rotary vane (DRV Series) — coaters with receiver, oil-free: DRV100, DRV140, DRV250, DRV400.

Dry claw (CL Series) — robust against fat and fines with a filter: CL150, CL251, CL300.

Roots vacuum blowers (RBV Series) — bulk pump-down of large coaters, with a dry pump finishing: RBV065, RBV100.

Liquid ring (LS Series) — fish meal evaporators: LS275-220, LS410-320.

Coater to pump. Tell us the batch size, cycle, set pressure and whether coaters alternate, and we will size the receiver and the pump — and the cyclone and filter in front of it. Talk to an engineer.