Dr.Vakuum
Alle Anwendungen

Reading a performance curve: pumping speed, ultimate pressure and the knee

7 Min. Lesezeit

A datasheet gives you two numbers: nominal pumping speed and ultimate pressure. Neither is where your process runs. The performance curve is the only place a pump tells you what it does at your pressure, and reading it well is the difference between a machine that fits and one that is 40 % too small in the one decade that matters. Every series page on this site carries its curve with the models overlaid; this note is the key to them.

1. The axes

A vacuum pump curve plots pumping speed (m³/h, or L/s for high vacuum) on the vertical axis against inlet pressure (mbar absolute) on the horizontal. Both axes are normally logarithmic, because the interesting behaviour spans three or four decades of pressure: a pump that is flat from 1,000 to 10 mbar and dies between 1 and 0.5 mbar cannot be drawn on a linear axis without the last decade becoming a single pixel.

On a log axis equal distances are equal ratios. The gap between 1,000 and 100 mbar is the same width as between 1 and 0.1. The habit to build: read the decade first, then the position inside it. The tick marks are at 2, 3, 4 … 9 within each decade and are not evenly spaced.

Pressure runs from atmosphere on the right to the ultimate on the left, so a pump curve is read right to left — the direction the process travels during pump-down.

2. Three regions of every pump curve

Look at the V Series curve. Every positive-displacement pump has the same three regions:

  1. The plateau. From atmosphere down to somewhere between 100 and 10 mbar the speed is essentially the pump's displacement — the swept volume per revolution times speed. Here the pump is a volumetric machine and the gas density does not matter yet.
  2. The knee. Speed begins to fall as internal leakage back across the vanes, the oil film or the clearances becomes a significant fraction of the displacement. For a single-stage vane pump the knee is at 5–20 mbar; for a two-stage at 0.1–0.5 mbar; for a liquid ring pump at 100–200 mbar, because the water's vapour pressure starts to take up the swept volume.
  3. The fall to ultimate. Below the knee the curve drops steeply to zero at the ultimate pressure — where back-leakage equals displacement and no net gas is removed. A single-stage V Series pump reaches 0.5 mbar; a two-stage DV Series reaches 5 × 10⁻³ mbar; a liquid ring pump 33 mbar.

Why does the knee matter more than the ultimate?

Because processes run near the knee, not near the ultimate. A packaging machine at 5 mbar on a 0.5 mbar pump is one decade above the ultimate, right at the knee of a single-stage curve, where the pump has perhaps 60–70 % of its nominal speed. The same machine on a two-stage pump with a 5 × 10⁻³ mbar ultimate is three decades above the ultimate, still on the plateau, with 95 % of nominal speed. The two pumps may have the same nominal figure, and the second one evacuates the chamber a third faster. Choose a pump whose knee is below your working pressure, and the ultimate will take care of itself.

3. 50 Hz, 60 Hz and the two curves

Most curves are drawn for both frequencies, 60 Hz about 20 % higher. Thailand is 50 Hz. The temptation to read the 60 Hz line because it is the upper one is real and expensive; the Dr.Vakuum charts are drawn at 50 Hz for that reason, and our datasheets give both figures with 50 Hz first. If a pump is to run on a variable-speed drive the curve scales almost linearly with speed in the plateau region and less than linearly near the ultimate, where leakage does not slow down with the motor.

4. Blower curves run the other way

A blower curve plots flow against differential pressure, and the differential is usually on the vertical axis in a linear scale: the 1SC and 2SC side channel curves and the RB Roots curve all look like this. The reason is that a blower's range of pressure is small — a few hundred millibar — while its range of flow is wide, so the interesting behaviour is in how quickly flow collapses as the differential rises.

Side channel curves are convex and steep: flow at open inlet is the nominal figure, and it falls to zero at the maximum differential, 200–400 mbar for one stage. The useful part is the upper half of the flow range; below that the blower is converting most of its power into heat. Roots blower curves are nearly vertical lines: a Roots machine is positive-displacement and its flow hardly changes with pressure, which is why they are drawn as one line per speed and the pressure limit is a thermal one, not a flow one.

The conversion to the pump convention is simple: differential below atmosphere = 1,013 − absolute. A blower rated at "−400 mbar" works down to 613 mbar absolute, and that is the number to place on the pump map in Vacuum pump or blower?.

5. Finding the operating point

A curve alone does not tell you where the pump will run. The process does. There are two cases.

Batch pump-down (closed vessel). The pump walks the curve from right to left; the pressure reached after time t comes from integrating the curve. Practically: split the pump-down into decades, read the average speed in each decade from the curve, and sum t = (V/S_decade) × ln(10) for each. For a 2 m³ vessel on a V140 (132 m³/h on the plateau, about 90 m³/h averaged across 10–1 mbar):

  • 1,013 → 100 mbar: (2 / 132) × 2.3 h = 0.035 h = 2.1 min
  • 100 → 10 mbar: (2 / 130) × 2.3 = 2.1 min
  • 10 → 1 mbar: (2 / 90) × 2.3 = 3.1 min

Total about 7.3 minutes to 1 mbar — of which almost half is the last decade. That is the knee at work, and why the simple formula with a single speed underestimates.

Continuous gas load (leak, vapour, process gas). Draw the gas load on the same chart as a second line: at any pressure p, the load Q (in mbar·m³/h) needs a speed S = Q/p. On log-log axes that is a straight line of slope −1. Where it crosses the pump curve is the operating point. Nothing else can happen: above that pressure the pump removes more than arrives and the pressure falls; below it, the opposite.

A CNC table leaking 200 m³/h of free air (Q ≈ 200 × 1,013 = 202,600 mbar·m³/h) against a 1SC529 blower: at 760 mbar absolute the load line needs 267 m³/h; at 800 mbar it needs 253 m³/h. The blower delivers about 250 m³/h at 220 mbar differential (793 mbar absolute). The table holds about 220 mbar of vacuum, and no gauge will ever show more. To hold 300 mbar you reduce the leak or buy a bigger line, not a "stronger" blower of the same size.

6. Comparing two machines honestly

  • Same frequency, same units, same reference. Nominal speed in m³/h at the inlet; "displacement" and "free air delivery" differ by the volumetric efficiency.
  • Compare at the working pressure, read off both curves, not at the nominal point. Two 300 m³/h pumps can differ by a factor of two at 2 mbar.
  • Check the ultimate with gas ballast open if the process has vapour. The V Series ultimate rises from 0.5 to about 1–2 mbar with ballast; the DV from 5 × 10⁻³ to 4 × 10⁻² mbar. The ballast-open curve is the one you will actually run.
  • Look at the power curve, where given. Liquid ring and side channel power peaks at a specific pressure, not at the deepest one; a motor sized for the ultimate can be overloaded in the middle of the range.

7. The Dr.Vakuum charts

Every series page shows one chart with every model as a curve, read at 50 Hz, log–log for pumps and linear-pressure for blowers. Hover a curve to read the speed at any pressure, or open a model page to see its own curve highlighted against the siblings — the V140 page is a good example, as is the RBV125. The curves are reconstructed from our own measured data in Dr.Vakuum units; where a datasheet and the curve disagree, the curve wins, because the curve is what the process will see.

Recommended Dr.Vakuum machines, by where the knee sits

Working pressure of your process Knee must be below Series Example
300–800 mbar abs (holding, conveying) n/a — blower region 1SC, 2SC, RBV 1SC529
100–300 mbar abs 100 mbar CL, DRV CL150
50–200 mbar abs, wet 100–150 mbar LM, LT LM200-065
5–50 mbar abs 5 mbar V V140
0.5–5 mbar abs 0.5 mbar DV, DSI DV90, DSI300
0.01–0.5 mbar abs 0.01 mbar MB booster + backing MB600 + V301

Send us the curve you were quoted. We will overlay it on the Dr.Vakuum equivalent at your working pressure and 50 Hz, and tell you what the difference means in cycle time or holding pressure. Talk to an engineer.