Thailand's pharmaceutical manufacturers — generic API and formulation plants in Bang Pa-in and Samut Prakan, herbal extract producers, veterinary and food-supplement makers — dry most of their intermediate and finished powders in vacuum tray dryers and vacuum ovens. The reason is temperature: at 20–50 mbar, water boils at 18–33 °C and ethanol at 5–15 °C, so a heat-sensitive active or an extract loses its solvent without losing its potency, colour or crystal form. The pump that holds that pressure is sized by the vapour load and chosen by what the vapour is, and a GMP suite adds requirements of its own.

1. How a vacuum tray dryer dries

Trays of wet cake (20–60 % solvent by weight after a filter or centrifuge) sit on heated shelves in a sealed cabinet. The cabinet is evacuated; the shelves are heated with hot water or thermal oil at 40–80 °C; the solvent evaporates at the pressure's boiling point and travels to a condenser where it is recovered as liquid; the vacuum pump removes air and the vapour the condenser misses. Drying proceeds in two phases:

  • Constant-rate period. The cake surface is wet; evaporation is limited by the heat the shelf can deliver. The vapour load is at its maximum and nearly constant — this is what sizes the condenser and the pump.
  • Falling-rate period. The surface is dry; solvent must diffuse out from inside the cake, and the rate falls as moisture content falls. Long, and limited by the product, not the equipment. The pump load falls to leakage plus a trickle of vapour; its job becomes holding the final pressure (often deeper, 5–10 mbar) to pull the last solvent out.

A typical cycle: 8–24 hours; the first 2–6 hours are constant-rate.

Why does the pump see so little of the solvent?

Because the condenser is between the dryer and the pump and is sized to condense almost all of it. The condenser runs at a temperature well below the solvent's boiling point at the dryer pressure: for water at 30 mbar (boiling 24 °C), a condenser at 5 °C condenses about 70 %; a condenser at −20 °C condenses over 95 %. The pump handles the remainder, saturated at the condenser temperature, plus air leakage. If the condenser is too warm — a common finding on dryers run on cooling-tower water in Thailand — the pump sees most of the vapour instead, cannot hold the pressure, and the cycle stretches by hours while the pump oil fills with solvent. The condenser is the first thing to check on a slow dryer.

2. Sizing a 24-tray dryer

A 24-tray pharmaceutical dryer, 2 m³ chamber, drying 150 kg of wet cake containing 60 kg of ethanol–water (70:30) at 40 mbar, shelf temperature 50 °C, condenser on glycol at −10 °C. The constant-rate period removes 45 kg of the 60 in 3 hours: 15 kg/h of vapour.

Condenser. Ethanol's vapour pressure at −10 °C is about 6 mbar, water's 2.6 mbar; at 40 mbar dryer pressure the condenser removes roughly 85 % of the ethanol and 93 % of the water. Residual vapour to the pump: ~2.5 kg/h, mostly ethanol. Condenser duty: 15 kg/h × ~900 kJ/kg ≈ 4 kW of refrigeration at −10 °C — a small glycol chiller.

Pump, holding duty. 2.5 kg/h of ethanol vapour at 40 mbar and −5 °C ≈ 2.5 × (8.314 × 268 / 46) / 4,000 Pa ≈ 30 m³/h; plus air leakage of 3 kg/h ≈ 2.4 Nm³/h → at 40 mbar ≈ 60 m³/h. Total ≈ 90 m³/h at 40 mbar, and more margin for the falling-rate period at 10 mbar where the leakage alone is 240 m³/h of actual volume.

Pump, pump-down. 2 m³ to 40 mbar in 10 minutes: (2/0.167) × 3.2 ≈ 38 m³/h — not the governing case.

The pump is therefore ~150 m³/h with a 10 mbar working pressure and ethanol in the gas. Three candidates:

  • Dry screw DSI150 (150 m³/h, 0.05 mbar): the modern pharma choice. Oil-free, so no hydrocarbon exhaust and no oil to validate; the rotors run hot and pass the ethanol to an exhaust-side condenser where the rest of it is recovered at atmospheric pressure; nitrogen purge on the seals for flammable solvents. ATEX internal-zone versions for solvent dryers.
  • Oil-sealed vane V140 (132 m³/h, 0.5 mbar) with gas ballast open and an inlet cold trap: the traditional and cheaper choice, acceptable where the product is not flammable-solvent-based (water-wet cakes) and the exhaust is ducted outside. Ethanol dissolves in the oil and is not purged out; oil change every 300–500 hours on solvent duty.
  • Dry vane DRV140: only if the dryer never goes below 100 mbar — rare on a pharma dryer. Used on warm-water drying of non-sensitive materials.

3. Solvent recovery and the atmosphere

Where the solvent is worth recovering or must not be emitted (toluene, dichloromethane, acetone, ethyl acetate), the layout is: dryer → primary condenser (chilled, −10 to −25 °C) → knock-out pot → dry screw pump → exhaust condenser (cooling water is enough at atmospheric pressure, where the solvent's dew point is far higher) → activated-carbon polisher → vent. The recovered solvent from both condensers is combined. This arrangement recovers 97–99 %, and it is the configuration behind the solvent recovery in a fine chemical plant note.

Water-wet cakes (most inorganic salts, many extracts) need only a cooling-water or chilled-water condenser and can use a liquid ring pump (LM200-065) where seal water is acceptable — a common choice in chemical plants, less so in GMP suites because of the water.

4. GMP, cleanability and the plant room

  • The pump is outside the GMP suite, in a technical area, connected through a wall; the suite sees only a stainless vacuum line and a sanitary isolation valve.
  • The vacuum line and knock-out pot are part of the cleaning validation: stainless, cleanable, with a CIP or manual-clean procedure, and a sterilising-grade filter on the vacuum break (the air admitted to release the vacuum) so the dried product is not recontaminated.
  • Exhaust of the pump treated as process emission: condenser, carbon, and for an oil-sealed pump an oil mist separator — hydrocarbon mist in a pharma plant's exhaust stack is a finding.
  • Documentation: IQ/OQ for the pump as part of the dryer; the pump's ultimate and the dryer's leak rate (pressure rise test, e.g. < 1 mbar/min with the dryer isolated) are recorded at qualification and checked at each requalification.
  • ATEX: a solvent dryer's interior is Zone 0 or 1; the pump's internal zone rating matches it, with gas-tight seals and a temperature interlock. Nitrogen inerting of the dryer before the pump starts.

5. Other vacuum dryers

The same arithmetic applies, with the chamber shape changed:

  • Vacuum paddle / conical dryers (agitated, for powders and pastes): larger vapour rates because of mixing; dust to the condenser; a cyclone or filter before the pump. Dry screw.
  • Vacuum belt dryers (extracts, instant beverages): continuous, large vapour load at 10–30 mbar; Roots booster on a dry screw or liquid ring — see When a Roots booster pays.
  • Freeze dryers: a special case at 0.1–1 mbar with the condenser at −50 °C or below — the freeze-drying pilot plant note.
  • Vacuum ovens, laboratory: 50–250 L, water or solvent, a DV16 or V21 with a cold trap — the laboratory vacuum note.

6. Worked dryers

Dryer Charge Solvent Pressure Residual vapour + leak at pump Dr.Vakuum answer
6-tray lab/pilot, 0.3 m³ 20 kg Water 30 mbar ~15 m³/h V21 + cold trap
24-tray GMP (above), 2 m³ 150 kg Ethanol–water 40 → 10 mbar ~150 m³/h DSI150 + exhaust condenser
48-tray chemical, 5 m³ 400 kg Water 50 → 20 mbar ~250 m³/h LM270-155 or V301
Paddle dryer, 3 m³ 1,200 kg Toluene 20 → 5 mbar ~300 m³/h DSI300 ATEX + cyclone + two condensers
Belt dryer, continuous 200 kg/h water Water 15 mbar ~1,500 m³/h MB600 + LT230-160V

Recommended Dr.Vakuum machines

Dry screw (DSI Series) — GMP and solvent dryers, oil-free, solvent recovery on the exhaust side: DSI150, DSI300.

Oil-sealed vane (V / DV Series) — water-wet cakes and non-GMP dryers, gas ballast open, cold trap: V21, V140, V301, DV16.

Liquid ring (LM / LT Series) — chemical dryers on water, large belt dryers: LM200-065, LM270-155, LT230-160V.

Roots boosters (MB Series) — belt dryers and deep final drying: MB300, MB600.

Dryer to pump. Tell us the charge, the solvent, the drying pressure profile and the condenser temperature you can reach, and we will size the condenser and the pump together and say which technology your product and your auditor will accept. Talk to an engineer.