Dr.Vakuum
การประยุกต์ใช้งานทั้งหมด

Vacuum bagging, RTM and composite curing: holding −950 mbar for hours

อ่าน 7 นาที

Thailand's composites industry makes boat hulls in Phuket and Samut Prakan, wind blade sections, bus and truck panels, carbon-fibre motorcycle and automotive parts, and a growing volume of aerospace sub-assemblies. Almost all of it is consolidated or infused under a vacuum bag: a flexible film sealed over the layup so that atmospheric pressure — up to 10 tonnes per square metre — presses the laminate while the resin cures. The pump holding that bag is unglamorous and critical, and it is sized by a quantity most shops never measure: how fast the bag leaks.

1. What the vacuum does

Under a bag at −950 mbar gauge (about 50 mbar absolute), the atmosphere applies 0.96 bar — 9.6 N/cm² — evenly over the whole part. That pressure:

  • Consolidates prepreg or wet layup, squeezing out excess resin and air to reach the designed fibre volume fraction.
  • Removes volatiles — air trapped between plies, moisture in the fibre, solvent and reaction products from the resin — before the resin gels, so the laminate has low void content (under 1–2 % for structural parts).
  • Drives resin flow in vacuum infusion: dry fibre under the bag, resin drawn in from a pot at atmosphere by the pressure difference.
  • Holds the part to the mould so it keeps the mould's shape through cure.

Depth matters here. Each 10 mbar of absolute pressure left in the bag is 10 mbar less consolidation pressure and a gas that stays in the laminate. Aerospace specifications call for 50 mbar absolute or better at the bag; marine and industrial work at 50–150 mbar. So the pump must reach well below 50 mbar — oil-sealed rotary vane pumps with a 0.5 mbar ultimate are the composites-shop standard, and dry vane pumps at 90 mbar do not reach the bag pressure.

Why is the pump sized by the leak and not the part?

Because the bag's volume is small and is evacuated in a minute, after which the pump does nothing for six hours except remove the air that leaks in. A 20 m² layup under a bag has perhaps 50–100 L of free volume in the breather and bleeder fabrics; a 40 m³/h pump empties it in well under a minute. What the pump does for the rest of the cure is hold 50 mbar against the inflow through the sealant tape, the bag film's pinholes, the vacuum port fittings and — the usual culprit — the fold-overs ("pleats") in the bag at corners. If the leak is 1 m³/h of free air and the pump has 20 m³/h at 50 mbar, the bag sits at 50 mbar. If the leak is 10 m³/h, the bag sits wherever the pump curve meets the leak line — perhaps 300 mbar — and the part is scrap.

2. Measuring the leak: the drop test

Before the resin is mixed, the bag is evacuated and isolated and the pressure rise over a set time is read. The industry rule is less than 10 mbar rise in 5 minutes (some specs: 5 mbar in 10 minutes). The leak rate is

Q = Δp × V / t

For a bag with 80 L of free volume rising 10 mbar in 5 minutes: Q = 10 × 80 / 300 s = 2.7 mbar·L/s — about 0.01 m³/h of free air. A bag passing the drop test leaks almost nothing; the pump's holding duty is trivial if the bag passes. The pump size is therefore set by the shop's practice: how many bags, how fast the first pump-down must be, and how much margin against a bag that nearly passes.

In practice: a 40 m³/h pump holds a single large bag that passes its drop test with enormous margin, and shops size pumps at 20–60 m³/h per large part so a marginal bag (a leak of 1–3 m³/h) still holds below 100 mbar. A pump at the high end of that range also pulls the initial bag down fast enough to see the pleats seat before the resin is committed.

3. Resin volatiles and the resin trap

Vacuum infusion draws resin through the fibre toward the vacuum port. When the resin front reaches the port, resin goes down the line to the pump — unless a resin trap (a catch pot with a sight glass and a float shut-off) sits in the line. It always does, and it is emptied every cycle.

What passes the trap is vapour: styrene from polyester and vinyl ester resins (vapour pressure 6 mbar at 20 °C — it boils under the bag), amine from epoxy hardeners, water from the fibre. In an oil-sealed pump these condense into the oil with the usual result. Three defences:

  1. Gas ballast open throughout (see Gas ballast, water vapour tolerance and why pumps drown).
  2. A cold trap or activated-carbon canister on the inlet for styrene-heavy work; a 5 kg carbon canister takes a week of boat work before it needs changing.
  3. Oil changes on hours, not on calendar — 500 hours on infusion work, 1,000 on prepreg.

For a heated cure (oven or autoclave at 120–180 °C) the volatile load peaks early and then falls; the ballast handles it.

4. Several bags on one pump

A shop with six moulds does not want six pumps. A central vacuum manifold with a receiver and a valve and gauge per station serves them all, and the arithmetic is diversity: at any moment some stations are pumping down (high flow, briefly) and most are holding (nearly zero flow). Rules that work:

  • One receiver of 200–500 L held at 20–30 mbar; a new bag is evacuated into it in seconds through a large valve, and the pump recovers the receiver.
  • Pump sized for 1.5–2 bags pumping down simultaneously plus the holding leaks of the rest: for six large moulds, 100–150 m³/h — a V140, or two V63 for redundancy, since a pump failure mid-cure scraps every part on the manifold.
  • A non-return valve at every station, so a bag that bursts does not pull the others up before its valve is closed; and a vacuum switch with alarm on the manifold.
  • Resin trap at every station, not one at the pump.

5. Light RTM and closed-mould processes

Light RTM clamps a semi-rigid counter-mould onto the mould with vacuum in a double seal, then injects resin at low pressure with vacuum at the vent. Two vacuum levels: the clamping seal at −900 to −950 mbar (deep, small volume, must not fail) and the cavity at −500 to −800 mbar (controls the resin flow and the void content). A single pump with two regulators serves a station, or the seal is held by a small pump and the cavity by the shop manifold. The gas from the cavity carries styrene heavily; the carbon canister earns its keep.

Prepreg autoclave cure is the same bag physics at 7 bar external pressure; the vacuum line into the autoclave is held at −950 mbar until the autoclave pressure exceeds 1–2 bar, then vented to the autoclave to avoid drawing resin, and the pump sees the bag again on cool-down. The autoclave's vacuum system is a manifold with several ports and a pump of 60–140 m³/h, sized as above.

6. Worked shops

Shop Stations Pump-down target Flow Dr.Vakuum answer
Carbon motorcycle parts, small bags 4 × 20 L 50 mbar in 30 s ~20 m³/h V21 with receiver
Boat hull infusion, 60 m² 1 × 300 L 50 mbar in 2 min ~30 m³/h, margin for leaks V63 + large resin trap + carbon canister
Bus panel shop, 6 moulds 6 × 100 L 2 bags at once in 1 min ~90 m³/h V140, 300 L receiver, or 2 × V63
Aerospace prepreg, autoclave 8 ports 20 mbar bag 60–100 m³/h DV90 (two-stage; keeps speed at 20 mbar)
Light RTM cell seal + cavity −950 / −700 mbar 10 + 20 m³/h V40 with two regulators

Recommended Dr.Vakuum machines

Single-stage oil-sealed vane (V Series) — the composites-shop pump: 0.5 mbar ultimate, gas ballast, oil mist separator. V21 (20 m³/h), V40 (40 m³/h), V63 (63 m³/h), V140 (132 m³/h).

Two-stage oil-sealed vane (DV Series) — aerospace bags specified below 30 mbar, where the single-stage knee costs time: DV60, DV90.

Every station: resin trap with float shut-off, non-return valve, gauge; styrene work: carbon canister; always: ballast open.

Shop manifold. Tell us the number of moulds, the typical bag size and your drop-test limit, and we will size the pump, receiver and traps. Talk to an engineer.