Dr.Vakuum
การประยุกต์ใช้งานทั้งหมด

Vacuum lamination presses and vacuum reflow in PCB and SMT assembly

อ่าน 7 นาที

Thailand's electronics sector — the Eastern Seaboard and Ayutthaya clusters that build hard-disk drives, power electronics, automotive ECUs and the boards inside them — uses vacuum at three points in making and populating a printed circuit board. The three duties look alike (a chamber, a press, a pump) and are sized quite differently.

1. Multilayer lamination presses

A multilayer PCB is a stack of etched cores and prepreg (resin-coated glass cloth) pressed at 170–200 °C and 20–40 bar until the resin flows and cures. The press platens sit inside a vacuum chamber evacuated before and during the heat-up, for two reasons: to pull air and moisture out of the prepreg so the laminate has no voids or delamination, and to lower the pressure above the resin so volatiles leave it instead of forming bubbles.

Typical cycle: close chamber → evacuate to 1–5 mbar in 10–20 minutes → heat and apply pressure under vacuum → cure 60–90 minutes → vent. The chamber is large (2–8 m³ for a production press) and contains the platens, a lot of steel, and the stack itself.

The gas load is outgassing: water and resin volatiles from prepreg that has been stored in Thai humidity. The pump must reach a pressure where remaining volatiles boil out of the resin before it gels, and it must handle those volatiles — mostly water vapour, some solvent residues from the prepreg varnish (methyl ethyl ketone, acetone, dimethylformamide in older systems).

Sizing. A 4 m³ chamber to 2 mbar in 15 minutes:

S = (4 / 0.25 h) × ln(1,013 / 2) = 16 × 6.2 ≈ 100 m³/h — plus the knee, so 150–200 m³/h

The final pressure sits one decade above a single-stage pump's ultimate, right at its knee; the pump will spend most of the 15 minutes below 10 mbar. A two-stage oil-sealed pump with a 5 × 10⁻³ mbar ultimate (DV175, 160 m³/h) keeps full speed through the whole cycle and gives margin as the outgassing rises with temperature. Run it with gas ballast open for the water, and fit a condensate trap on the inlet. Oil-sealed is acceptable here — the press room is not the clean assembly line, and the chamber is a sealed vessel — though a plant with a strong hydrocarbon-free policy will choose a dry screw (DSI150) and accept its 0.05 mbar ultimate, which is more than enough.

Why does the press need ultimate pressure but the laminator needs speed?

Because the press is a slow, closed process where the final pressure determines void content — the volatiles must be pulled out of the resin before it cures, and that happens only below a few millibar. The laminator, below, is a fast cyclic process where the board is in the chamber for seconds; it only has to reach a pressure at which the film conforms, and it has to reach it hundreds of times an hour. One is sized on the last decade of the curve; the other on the first.

2. Vacuum laminators for dry film and solder mask

Photoresist dry film and liquid-photoimageable solder mask are applied in vacuum laminators: the panel goes into a shallow chamber, the chamber is evacuated to 5–20 mbar in 10–30 seconds, a heated silicone diaphragm presses the film onto the panel, air is admitted above the diaphragm to force conformity into every via and trace edge, and the chamber opens. Cycle time 40–90 seconds; chamber volume 50–200 L.

This is a short-cycle chamber duty, and the pump is sized on cycle time:

S_eff = (0.15 m³ / 20 s) × ln(1,013 / 10) × 3,600 = 0.0075 × 4.6 × 3,600 ≈ 125 m³/h

A V140 single-stage pump does it. But the laminator stands in the imaging area next to the exposure units, usually in a yellow-light clean zone, and here oil mist is a defect cause — a film of oil on a panel before solder mask is a wetting fault that shows up at electrical test. A dry pump is the right choice: a DRV100 dry vane pump if the laminator's set point is above 90 mbar (some are), or a DSI150 dry screw if it is 5–20 mbar. Dry claw (CL150, 150 mbar ultimate) is too shallow for most laminators. Fit a vacuum receiver of 200–500 L between the pump and the laminator: the receiver is held at the set point between cycles and the chamber is evacuated into it in a few seconds, so a smaller pump running continuously replaces a larger one running in bursts.

3. Vacuum reflow and vapour-phase soldering

Solder joints formed in a normal reflow oven contain voids — gas bubbles from flux volatiles trapped as the solder solidifies. For most components a few percent void area is harmless. For power semiconductors, LEDs and anything whose thermal path is the solder joint — the power modules and automotive inverters built in Thailand — voids are a reliability defect, and IPC-7093 and the automotive customers set limits of 2–5 %.

Vacuum reflow applies vacuum to the board while the solder is molten. The oven's final heating zone becomes a chamber that is evacuated to 10–100 mbar for 10–30 seconds; the voids expand, rise and burst at the surface, and the solder closes behind them. Void area falls from 10–20 % to under 2 %. Vapour-phase soldering systems do the same inside the vapour blanket.

The pump duty: a hot chamber (240 °C solder, 150–200 °C walls), a volume of 50–150 L, evacuated to 10–50 mbar in 10 seconds, every board. The gas is hot air with flux volatiles — rosin, activators, glycols — that condense into sticky residue on anything cooler than about 100 °C. So:

  • Speed: (0.1 m³ / 10 s) × ln(1,013 / 30) × 3,600 ≈ 125 m³/h, or a smaller pump with a receiver as above.
  • Dry, because the reflow line is the SMT line, and an oil mist exhaust in that room is intolerable.
  • Flux handling: a heated inlet line, a cooled flux condenser or trap immediately before the pump with a drain, and a pump that runs hot and tolerates the residue that gets through. The dry screw pump's hot rotors keep volatiles in the vapour phase through the machine; dry vane pumps will gum.

A DSI150 with a flux trap and a nitrogen purge on the seals is the configuration we recommend for vacuum reflow. For a vapour-phase system, where the pump sees the perfluorinated heat-transfer fluid as well, the trap becomes a chilled condenser that returns the fluid to the tank — it is expensive, and the pump must not consume it.

4. The clean-zone rules

Whatever the duty, pumps installed in or adjacent to PCB imaging and SMT areas follow a few rules:

  • Oil-free in the room. If an oil-sealed pump is used (the press room), its exhaust is ducted outside through a coalescing separator, and the pump is not in the clean zone.
  • Exhaust outside, always. Flux fumes and prepreg volatiles are irritants; vacuum pump exhaust is treated as process exhaust.
  • Particles. Dry pumps emit no particles; a dry vane pump emits carbon dust from vane wear into its exhaust only, which is ducted.
  • ESD. Pump frames bonded to the line earth; flexible hose conductive-grade.
  • Noise. Imaging rooms are quiet; a 70 dB(A) pump next to an operator is a complaint. The DRV and DSI machines run 65–72 dB(A); a cabinet or a plant-room location brings that below the room level.

5. A worked line

A rigid-board plant: one 6-opening multilayer press (chamber 5 m³), two dry-film laminators (120 L, 60 s cycle, 15 mbar), one solder-mask laminator (200 L, 90 s, 10 mbar), one vacuum reflow oven (80 L, 20 s, 30 mbar).

Duty Target Flow at duty Dr.Vakuum answer
Lamination press 2 mbar, 15 min ~180 m³/h, two-stage DV175 + condensate trap, ballast open
Dry-film laminators (2) 15 mbar, 20 s ~90 m³/h each One DSI150 with a 500 L receiver serving both
Solder-mask laminator 10 mbar, 30 s ~110 m³/h DSI150 with 300 L receiver
Vacuum reflow 30 mbar, 10 s ~125 m³/h peak DSI150 + heated line + flux trap

Three dry screw pumps of one size simplify spares; the press keeps an oil-sealed two-stage machine because its ultimate pays for itself in laminate quality.

Recommended Dr.Vakuum machines

Dry screw (DSI Series) — the clean-zone default: oil-free, 0.05 mbar ultimate, hot rotors that pass flux and resin volatiles. DSI150 (150 m³/h), DSI300 (300 m³/h).

Two-stage oil-sealed vane (DV Series) — lamination presses, where the last decade decides void content: DV90, DV175, DV275.

Dry rotary vane (DRV Series) — laminators and handling with set points above 90 mbar: DRV60, DRV100.

For the component-handling vacuum on pick-and-place heads and board handling conveyors — high flow, shallow, blower territory — see Vacuum pick-and-place, lifting and robotic handling.

Line schedule. Send us the press chamber volume and cycle, the laminator models and set points, and whether the reflow oven has a vacuum module, and we will return a pump-by-pump schedule with trap and receiver sizes. Talk to an engineer.