Vacuum packaging of frozen seafood and meat: sizing the chamber machine pump

อ่าน 7 นาที

Thailand ships over a million tonnes of frozen shrimp, fish and poultry a year, and almost every retail or food-service pack of it is vacuum packed on a chamber machine. The pump on that machine is sized by one question — how many cycles per hour at what chamber pressure — and is killed by one thing: water vapour from frozen product pumped by a cold oil-sealed pump. This note covers both.

1. What the chamber machine does

Product in a barrier bag goes into a chamber; the lid closes; the chamber is evacuated to a set pressure; the bag is heat-sealed under vacuum; air re-enters and the bag collapses onto the product. For shelf-life the residual oxygen in the pack is what matters, and that is set by the chamber pressure at the moment of sealing:

Chamber pressure at seal Residual air Typical use
50 mbar 5 % Dry goods, cheese
10 mbar 1 % Fresh meat, fish fillets
5 mbar 0.5 % Export shrimp, long-life packs
2 mbar 0.2 % Specialist; fresh product will start to boil

The last line is the physical limit. Water at 2 °C has a vapour pressure of 7 mbar; pull a chilled fillet below that and its surface water boils, the bag inflates with vapour and the pack "puffs" at the seal. For fresh, chilled product 5–10 mbar is the floor. For frozen product at −18 °C the vapour pressure is only 1.2 mbar, so deep vacuum is possible — and that is where the vapour problem begins.

2. Sizing by cycle time

The chamber is a closed volume with no significant gas load during pump-down (the bag is sealed; the product releases little), so the pump-down equation applies directly:

t = (V / S_eff) × ln(p₀ / p₁)

A double-chamber machine with two 150 L chambers evacuates one while the operator loads the other. Target 5 mbar, required pump-down 15 s:

S_eff = (0.15 / 15 s) × ln(1013 / 5) × 3600 = 0.01 × 5.31 × 3600 ≈ 191 m³/h

Three corrections before choosing a pump:

  • The last decade is slow. A single-stage vane pump with a 0.5 mbar ultimate loses speed below about 10 mbar, so the time from 10 to 5 mbar is longer than the formula suggests. Carry 20 % margin or use the pump's curve directly.
  • Internal piping. The machine's internal manifold and lid valve are usually generous; the speed lost is 10–15 %, not the 50 % seen on badly piped vessels.
  • Product volume. Subtract the product from the chamber volume; a chamber full of shrimp blocks has a quarter of its empty volume to pump. Size on the worst case — small loads of flat fillets.

A V301 at 300 m³/h gives that double-chamber machine a 10-second pump-down to 5 mbar; a V140 gives about 22 s, acceptable on a single-chamber machine where loading takes that long anyway.

Rule of thumb by machine class

Machine Chamber volume Cycles/h Pump
Tabletop 20–40 L 60–120 20–25 m³/h — V21
Floor-standing single 80–150 L 90–150 63–100 m³/h — V63, V100
Double chamber 2 × 120–200 L 200–300 140–300 m³/h — V140, V301
Belt / automatic 200–400 L 300+ 300–640 m³/h — V301, V630

3. Why do oil-sealed pumps drown on frozen product?

Frozen product carries frost. Shrimp blocks are glazed with ice. Every cycle, some of that water sublimes or melts into the chamber, and the pump inhales it as vapour. Inside the pump the gas is compressed from 5 mbar to atmosphere — a 200:1 ratio — and vapour compressed that much condenses unless the pump is hot enough to keep it above its dew point. Condensed water in the oil forms an emulsion, the oil loses its sealing and lubricating properties, the ultimate pressure rises, the cycle slows, and in a few weeks the vanes and bearings are corroded.

The pump is rated for this: the V140 has a water vapour tolerance of 2 kg/h with gas ballast open, the V301 4.5 kg/h, the V630 17 kg/h. Three habits make the rating real:

  1. Run with gas ballast open. The ballast admits a small flow of air into the compression stage so the vapour stays below its saturation pressure. It costs 0.2–0.5 mbar of ultimate — irrelevant at 5 mbar — and it is the single most ignored setting on a packaging pump.
  2. Run the pump hot. A pump at 70–80 °C does not condense vapour; a pump started cold at 06:00 and fed frozen product immediately does. Warm up for 15–20 minutes against a closed inlet or on a dry cycle.
  3. Run 30 minutes with the inlet closed at end of shift. This boils the absorbed water back out of the oil. Oil that turns milky anyway should be changed, not topped up.

For a line that packs frozen product all day, we also fit a cold trap or chilled condenser on the manifold — a few hundred watts of refrigeration catches most of the vapour before the pump — and specify the DV Series two-stage pumps where the chamber pressure is set below 5 mbar, because their higher compression stage runs hotter and their gas ballast is sized for it.

4. Gas flush and modified atmosphere

Many shrimp and fish lines flush the pack with CO₂/N₂ before sealing. The sequence is evacuate → flush to ~600 mbar → evacuate → flush → seal, or a single flush. Two consequences for the pump:

  • The pump sees more gas per cycle, since it evacuates twice. Size on the total.
  • CO₂ dissolves in oil and in water, raising the vapour-handling problem slightly. Gas ballast handles it.

MAP packs for chilled seafood typically seal at 300–500 mbar, not deep vacuum. If the line is MAP-only, a dry-running pump can replace the oil-sealed one entirely: a DRV60 or DRV100 reaches 90 mbar, well below the MAP seal pressure, with no oil and no vapour problem.

5. Installation in a washdown plant

Seafood plants are wet, cold (8–12 °C) and washed with chlorinated water. The pump room should not be.

  • Install the pump in a separate, ventilated plant room or an enclosure with the exhaust ducted outside. Oil mist and fish do not belong in the same air.
  • Inlet filter rated for liquid: brine droplets and scales do reach the manifold.
  • Exhaust oil mist separator — standard on V Series, but check the element on the maintenance schedule.
  • Hoses, not rigid pipe, between machine and pump, so the machine can be moved for cleaning without disturbing the pump.
  • Where the machine itself must be in the cold room, pick the larger motor variant for 50 Hz running at 10 °C ambient — oil is thick when cold and starting torque is higher.

6. A worked plant

A shrimp exporter with four double-chamber machines, 2 × 160 L each, target 5 mbar in 12 s, frozen glazed product, no MAP.

  • Per machine: S_eff ≈ (0.16 / 12) × 5.31 × 3600 ≈ 255 m³/h → V301 (300 m³/h, 4.5 kg/h vapour)
  • Four pumps rather than one central 1,200 m³/h unit: chamber packaging is a sequence of 12-second pump-downs, and a central system would need a large vacuum receiver to deliver that peak; point-of-use pumps are simpler and each machine keeps running when one pump is serviced
  • A chilled condenser per machine, gas ballast locked open, warm-up timer on the control panel, oil change on a 500-hour schedule

Recommended Dr.Vakuum machines

Single-stage oil-sealed vane (V Series) — the standard chamber packaging pump: 0.5 mbar ultimate, high water vapour tolerance with gas ballast, integral oil mist separator.

Model Speed, 50 Hz Water vapour, ballast open Suits
V21 20 m³/h — Tabletop machines
V63 63 m³/h 1 kg/h Single chamber, 100–150 L
V140 132 m³/h 2 kg/h Single chamber fast, or small double
V301 300 m³/h 4.5 kg/h Double chamber, frozen product
V630 640 m³/h 17 kg/h Belt machines, central manifold

Two-stage oil-sealed vane (DV Series) — for lines sealing below 5 mbar or needing the fastest last decade: DV90, DV175.

Dry rotary vane (DRV Series) — MAP-only lines sealing at 300–500 mbar, oil-free: DRV60, DRV100.

Cycle check. Tell us the chamber size, the set pressure and the cycles per hour you need, and whether the product is frozen. We will size the pump from its curve and specify the vapour handling that keeps it alive. Talk to an engineer.