Dr.Vakuum
全部应用案例

Battery manufacturing: electrode drying, electrolyte filling and degassing

阅读 7 分钟

Thailand's EV policy has brought battery cell and pack plants to the Eastern Economic Corridor, and with them a set of vacuum duties that did not exist in the country five years ago. A lithium-ion cell is destroyed by water — a few hundred ppm of moisture in the electrode reacts with the electrolyte salt to form hydrofluoric acid, which attacks the cathode and the current collectors, so the cell loses capacity from its first cycle. Every step after coating is therefore about removing water and air and keeping them out, and most of those steps are done under vacuum.

1. The four vacuum duties

Step What vacuum does Pressure Gas Pump type
Electrode coil drying (vacuum oven, 80–150 °C, 12–48 h) Removes residual water and NMP solvent from the coated foil 0.1–10 mbar Water, NMP vapour, air Dry screw (+ booster)
Cell drying (after winding/stacking, before filling, 60–100 °C, 12–72 h) Removes moisture from the assembled jelly roll and separator to < 100–300 ppm 0.01–1 mbar Water, air Dry screw + booster
Electrolyte filling (in the dry room) Evacuates the cell so electrolyte wets every pore; multiple vacuum/pressure cycles 10–100 mbar (cell), 1 mbar (chamber) Electrolyte solvent vapour (EC/DMC/EMC), air Dry screw
Degassing and final sealing (after formation) Removes the gas generated in the first charge; cell is opened under vacuum, gas drawn, resealed 10–100 mbar Formation gases (CO₂, ethylene, H₂), solvent vapour Dry screw

All four are oil-free duties. A hydrocarbon from a pump's oil inside a cell is a contaminant; a cell plant's dry room (dew point −40 to −60 °C) cannot tolerate an oil-sealed pump's exhaust or the water that a liquid ring pump carries; and the solvents — NMP (N-methyl-2-pyrrolidone) and the carbonate electrolyte solvents — dissolve in oil and are recovered more cleanly without it. The DSI Series dry screw pumps are the machine for all four, with MB Series boosters where the speed at low pressure is needed.

Why is the drying step so long, and what does that mean for the pump?

Because the water is bound — adsorbed in the microporous electrode coating (which has an enormous internal surface) and in the polymer separator — and desorbs slowly, following a falling-rate curve that asymptotes toward the equilibrium moisture at the drying temperature. Getting from 1,000 ppm to 500 is quick; from 200 to 100 takes as long as everything before it. The pump's role through those hours is to hold a pressure low enough that the partial pressure of water above the electrode stays far below its equilibrium — the lower the better, which is why cell drying runs at 0.01–0.1 mbar — against a gas load that is small by the end (grams per hour of water, plus the chamber's leakage). So the pump is sized for the initial pump-down and the early high-vapour phase, must have an ultimate well below the process pressure (hence booster sets to 10⁻³ mbar), and must run for days at a time with water passing through it — which a dry screw does if its exhaust drains and its purge keeps the water as vapour.

2. Electrode and cell drying

Electrode coil dryers are vacuum ovens taking 10–50 coils (each a few hundred kilograms) at 100–150 °C, with the NMP that the coating dryer did not quite remove (hundreds of ppm) and the water the foil has adsorbed. The NMP is recovered: it is expensive and toxic, so the oven's vacuum line passes through a condenser at 5–10 °C (NMP has a low vapour pressure, 0.4 mbar at 20 °C, so it condenses easily) before the pump, and the pump sees mostly water and air. A 10 m³ coil-drying oven to 1 mbar in 30 minutes, then held at 0.1 mbar:

  • Pump-down: (10 / 0.5 h) × ln(1,013/1) ≈ 140 m³/h at the plateau; the knee below 10 mbar and the water load call for a booster.
  • Set: MB300 (1,000 m³/h) on a DSI150 — 0.1 mbar held against ~5 Nm³/h of leakage with ease; nitrogen purge on the DSI seals so water and NMP traces do not condense in the pump; exhaust to the plant's solvent abatement.

Cell drying ovens are smaller (1–5 m³), deeper (0.01–0.1 mbar) and hotter-constrained (the separator melts at 130 °C; 80–100 °C is the limit). A 3 m³ cell dryer to 0.05 mbar: MB150 on a DSI150, reaching 10⁻³ mbar ultimate, with the vacuum broken by dry nitrogen only — never room air — since the cells go straight to the dry room. Plants run many such ovens in parallel on staggered cycles, often from a central booster/screw set with a vacuum header and a receiver, sized on the diversity of the pump-down phases.

3. Electrolyte filling

The cell (pouch, prismatic or cylindrical) is placed in a filling chamber in the dry room; the chamber is evacuated to 1–10 mbar (drawing the air out of the jelly roll's pores); a metered dose of electrolyte is injected under vacuum; the chamber is pressurised with nitrogen to push the electrolyte into the pores; the cycle repeats two to five times. The cell is then pre-sealed.

The vacuum pump sees the electrolyte solvent vapour — ethylene carbonate, dimethyl carbonate, ethyl methyl carbonate (DMC has a vapour pressure of 55 mbar at 20 °C, so at a 10 mbar chamber pressure it boils) — plus nitrogen. The duty is a short-cycle chamber (10–50 L per filling station, cycled every 30–60 seconds, dozens of stations on a line) served from a vacuum header fed by a dry screw pump with a solvent condenser on its exhaust: a DSI300 serves 20–30 filling stations with a receiver, the condenser recovering the DMC/EMC that the pump passes. The electrolyte salt (LiPF₆) decomposes to HF with any moisture, so the pump and its lines are purged with dry nitrogen and the exhaust is scrubbed. Dry-room integration: the pump sits outside the dry room with the line through the wall, so its heat and purge gas do not load the room's dehumidifiers.

4. Degassing and sealing

After the first charge (formation) the cell has produced gas — CO₂, ethylene, hydrogen — in its gas pocket (pouch cells have a deliberate pocket for this). The pocket is pierced under vacuum, the gas drawn out, and the cell resealed and trimmed, in a degassing chamber at 10–100 mbar. Small volumes, short cycles, flammable gas at low concentration, electrolyte vapour: a DSI150 on a header, nitrogen purge, exhaust to abatement. The same pump set often serves the final sealing station.

5. What a cell plant asks of a vacuum pump

  • Oil-free, provably: hydrocarbon-free exhaust, and no lubricant in contact with the gas path.
  • Solvent-tolerant: NMP, carbonates, and the HF traces that electrolyte produces — stainless or coated gas-path parts, PTFE and FFKM seals.
  • Nitrogen purge on shaft seals and the exhaust to keep vapour above its dew point and dilute flammable gas.
  • Exhaust drain at the low point and a short exhaust run so condensed water or solvent cannot run back into a stopped pump.
  • Continuous duty for days (drying) and high cycle rates (filling) from the same model range — a plant standardises on two or three pump sizes.
  • Remote monitoring — temperature, current, purge flow — because the pumps are in a service corridor behind a dry-room wall.

The DSI Series meets this list: 0.05 mbar ultimate, dry, cooled rotors that run hot enough to pass vapour, purge ports, and 150–1,200 m³/h.

6. Worked plant: a 2 GWh pouch-cell line

Step Equipment Pressure Dr.Vakuum answer
Electrode coil drying 4 × 10 m³ ovens, staggered 0.1 mbar 2 × (MB300 + DSI150) sets on a header, NMP condenser per oven
Cell drying 8 × 3 m³ ovens 0.05 mbar 2 × (MB150 + DSI150), N₂ break
Electrolyte filling 24 stations, 30 L, 45 s cycle 5 mbar chamber 2 × DSI300 + 1 m³ receiver, solvent condenser on exhaust
Degassing / sealing 8 stations 50 mbar DSI150 + receiver

All pumps in the service corridor, exhausts to the plant's solvent abatement and HF scrubber, nitrogen purge metered per pump.

Recommended Dr.Vakuum machines

Dry screw (DSI Series) — every battery vacuum duty: DSI150 (150 m³/h), DSI300 (300 m³/h), DSI630 (630 m³/h).

Roots boosters (MB Series) — drying ovens below 0.1 mbar: MB150, MB300, MB600.

The electrode coating line upstream shares its exhaust and NMP recovery with the dryers; the pack assembly downstream uses leak test chambers for the pack enclosure — the same dry screw pumps, the same plant standard.

Line to pumps. Tell us the oven volumes and schedules, the number of filling stations and the dry-room dew point, and we will return a pump schedule with purge, condenser and header sizing. Talk to an engineer.