Thailand is one of the world's largest exporters of canned tuna, pineapple and sweetcorn, and a modern cannery runs at 400–1,200 cans per minute. Vacuum appears at three points on that line, each with a different pressure, a different gas and a different failure mode. A pump sized for one of them is wrong for the other two.

1. Headspace vacuum at the seamer

A vacuum seamer closes the can inside a sealed chamber at reduced pressure, so the headspace above the product is under vacuum when the double seam forms. The purpose is not preservation — the retort does that — but seam integrity and can shape: a can seamed at vacuum has concave ends that stay concave after processing, and the panel reversal on a swollen can becomes a reliable visual indicator of spoilage.

The target is typically 300–600 mbar absolute in the headspace (400–700 mbar vacuum, in the gauge terms a cannery uses). Deeper than that and the product boils or foams at filling temperature; a hot-fill at 85 °C has a vapour pressure of 580 mbar, so the chamber pressure must stay above it.

The duty is a classic short-cycle chamber: a small volume evacuated hundreds of times a minute. For a seamer with a 1.5 L chamber at 600 cans/min:

  • Air to remove per can at 1,013 → 400 mbar: 1.5 L × (613/1013) ≈ 0.9 L
  • Per minute: 600 × 0.9 L ≈ 550 L/min ≈ 33 m³/h of free air

Plus the leakage through the rotating chamber seals, which on a worn seamer doubles that. A pump of 60–100 m³/h per seamer head is the usual answer, and the deciding factor is not the flow but the gas: the inlet stream carries brine mist, oil from the product, sugar syrup and steam flash. That rules out some technologies immediately.

Why must the seamer pump be oil-free?

Because the pump inlet is open to the can headspace at the instant of seaming. An oil-sealed pump that back-streams oil mist — on shutdown, on a stalled cycle, through a failed non-return valve — puts mineral oil into a food container. The risk is small per cycle and unacceptable per year. A dry rotary vane pump has no oil in the working chamber, so the failure mode does not exist. The DRV40 at 48 m³/h and the larger DRV models are built for exactly this.

Dry vane pumps have a modest ultimate (90 mbar absolute), which is irrelevant here — the seamer needs 400 mbar, and the shallower ultimate is a benefit: it cannot pull a hot product into boiling.

Fit a liquid separator with a drain on the inlet (brine and syrup mist), and an inlet filter rated for the mist — change it by differential pressure, not by calendar.

2. Vacuum in the retort

Retorts sterilise the closed cans at 116–130 °C under steam or water spray. Vacuum enters in two ways:

Venting. Before the process temperature is reached, air must be driven out of the retort so the steam contacts every can; residual air creates cold spots that fail the F₀ calculation. Traditional venting blows steam to atmosphere for several minutes; a vacuum vent pulls the retort to 100–200 mbar first and then admits steam, saving 10–20 % of the cycle's steam and several minutes of cycle time. The volume is large (3–10 m³) and the time short (2–3 minutes), so the pumping speed is high and the gas is hot, wet air:

S = (V/t) × ln(1013/150) = (8 m³ / 0.042 h) × 1.91 ≈ 365 m³/h

A liquid ring pump such as the LM270-155 (375 m³/h) is the right machine here — it condenses the steam flash in its own seal water and does not care about the temperature.

Cooling. After sterilisation, cooling water is sprayed onto cans at 125 °C while the retort is held under overpressure (to stop the cans bursting), not under vacuum. No pump needed — but the cooling water that drains afterwards is often recovered through a vacuum deaerator, which brings us to the third duty.

3. Deaeration of juices, purées and sauces

Pineapple juice, tomato purée and fruit concentrates are deaerated before filling to remove the dissolved and entrained air that would otherwise oxidise vitamin C, brown the colour and cause foaming at the filler. The product is sprayed or filmed into a vessel at 60–100 mbar absolute, where the dissolved air comes out of solution in seconds.

The gas load is the air dissolved in the product plus the vapour flashing off:

  • Dissolved air in juice: about 20–30 mL of air per litre of product at saturation
  • 10,000 L/h of juice → 250 L/h of air at normal conditions
  • At 80 mbar and a product temperature of 25 °C (vapour pressure 32 mbar), vapour is 40 % of the gas volume and the inlet volume is roughly 250 × (1013/80) × (80/48) ≈ 5.3 m³/h — tiny

The pump is not sized on gas load here. It is sized on initial pump-down of the deaerator vessel and its tank, and on holding pressure against air in-leakage through the product pump seals and level glasses. A 1–2 m³ deaerator pulled to 80 mbar in 3 minutes needs about 100 m³/h; a single-stage oil-sealed vane pump such as the V100 does this comfortably and, since the pump never sees the product, oil-sealed is acceptable. Fit a chilled condenser or a knock-out pot between vessel and pump: at 80 mbar the product's own vapour condenses easily and should not reach the pump.

If the deaerator runs hot (hot-break tomato at 90 °C) the vapour pressure is 700 mbar and the vessel pressure cannot go below it; the vacuum is then mild and a dry vane pump is again the simple answer.

4. CIP and washdown

Everything in a cannery is washed with caustic, acid and hot water. The vacuum pumps are not CIP'd internally, but their inlet lines are, and the plant room is hosed down.

  • Mount pumps above the wash zone or on a plinth with the inlet rising, so CIP solution cannot drain into the pump.
  • Fit an automatic isolation valve that closes on CIP start.
  • Use IP55 motors at minimum; stainless steel guards, not painted mild steel.
  • Oil-sealed pumps: fit an exhaust oil mist separator so the pump room is not misted, which matters where food is handled nearby.

5. A worked line

A tuna cannery: two seamers at 300 cans/min each (1.2 L chambers), one 8 m³ retort with vacuum venting, one 1.5 m³ brine deaerator.

Duty Pressure Flow needed Dr.Vakuum answer
Seamer 1 400 mbar abs ~40 m³/h + seal leakage DRV60
Seamer 2 400 mbar abs ~40 m³/h + seal leakage DRV60
Retort vent 150 mbar abs, 2.5 min ~365 m³/h, wet, hot LM270-155
Deaerator 80 mbar abs ~60 m³/h pump-down V63 + condenser

Three technologies, four pumps, and no single machine that could have done all of it. That is normal; the mistake is trying to serve the seamers from the retort pump through a header, which puts hot wet air and brine into one system and makes every duty hostage to the other.

Recommended Dr.Vakuum machines

Dry rotary vane (DRV Series) — for the seamer and any duty open to the food: oil-free, 90 mbar ultimate, simple vane change. DRV25 (30 m³/h), DRV40 (48 m³/h), DRV60, DRV100.

Liquid ring monobloc (LM Series) — retort venting and any hot, wet duty: LM200-065 (105 m³/h), LM270-155 (375 m³/h).

Single-stage oil-sealed vane (V Series) — deaerators and vessels the pump never shares with the product: V63, V100, V140.

Line audit. Send us the seamer make and speed, retort volume and deaerator size and we will return a duty-by-duty pump schedule. Talk to an engineer.