Dr.Vakuum
全部应用案例

When a Roots booster pays: backing-pump combinations

阅读 7 分钟

A Roots booster — two lobed rotors in a casing, no oil in the chamber, no internal compression — is the cheapest way to add a large pumping speed in the band between 10 and 0.01 mbar. It is also the most misapplied vacuum machine we see: bought to "speed up" a pump-down that spends most of its time above 10 mbar, where the booster is a restriction, or run from atmosphere until the motor trips. This note is about where the booster pays, and how to pair it.

1. What a booster is and is not

The rotors trap gas at the inlet and carry it to the outlet, where it meets the backing pump's suction. There is no built-in compression: the pressure rise happens as gas from the outlet flows back into the trapped volume. So the booster can move a large volume (hundreds to thousands of m³/h from a small motor) but can only sustain a limited compression ratio — the outlet-to-inlet pressure ratio — before back-leakage through the clearances equals what it moves forward.

That compression ratio depends on the inlet pressure:

Inlet pressure Typical compression ratio (zero flow)
100 mbar 3–5
10 mbar 10–20
1 mbar 30–50 (peak)
0.1 mbar 20–40
0.01 mbar 10–20

The peak is around 1 mbar, where the gas is dense enough to seal the clearances by viscosity but thin enough not to leak back fast. That is why the booster's territory is 10–0.01 mbar: above it the ratio is too small to matter, below it molecular back-flow erodes it.

Why can't the booster run from atmosphere?

Because the power it draws is the volume it moves times the pressure difference across it, and at atmospheric inlet both are at maximum. An MB600 moving 2,000 m³/h against even 100 mbar of differential needs 2,000/3,600 × 10,000 Pa ≈ 5.5 kW of gas power, before losses — about its whole 7.5 kW motor. At 500 mbar differential it would need 28 kW. The booster must therefore be switched on only when the backing pump has brought the system below its cut-in pressure, typically 30–80 mbar, or protected by a bypass valve that opens when the differential exceeds a set value (usually 40–80 mbar) and lets gas flow around the rotors. Boosters with an integral bypass or a hydraulic-coupling drive can start from atmosphere and are used where simplicity of control matters; standard boosters have a pressure switch interlock.

2. The staging ratio

The booster's speed must be matched to the backing pump's. The staging ratio is booster displacement divided by backing pump speed:

  • 4–8 : 1 for a conventional set working at 10–0.1 mbar — e.g. an MB600 (2,000 m³/h) on a V301 (300 m³/h) is 6.7 : 1.
  • Up to 10–12 : 1 if the duty is mostly below 0.1 mbar and the booster's compression ratio is high there.
  • 2–3 : 1 where the gas load is heavy or the process pressure is above 10 mbar, to keep the booster's differential — and its temperature — down.

Too high a ratio starves the booster: it compresses to a differential it cannot sustain, overheats (the rotors expand, clearances close, seizure follows) and the actual speed collapses toward the backing pump's. Too low wastes the booster.

Effective speed at the inlet: approximately

S_eff = S_booster × K / (K + S_booster / S_backing)

For the MB600/V301 set at 1 mbar with K ≈ 40: S_eff = 2,000 × 40 / (40 + 6.7) ≈ 1,700 m³/h — 85 % of the booster's displacement, from a set whose backing pump alone gives 300. At 10 mbar with K ≈ 15: S_eff = 2,000 × 15 / 21.7 ≈ 1,380 m³/h. At 100 mbar with K ≈ 4: 750 m³/h, and the booster is working hard for a modest gain.

3. Pairings

Booster + oil-sealed vane (MB + V / DV). The classic set for furnaces, impregnation, degassing and large chambers. Reaches 10⁻² mbar with a single-stage V backing pump, 10⁻³–10⁻⁴ mbar with a two-stage DV. The booster also protects the oil-sealed pump: vapour and dust mostly pass the booster and the backing pump sees them at a higher pressure where they are easier to handle — and the booster's compression heat keeps vapour from condensing in it.

Booster + liquid ring (MB + LT). For wet, dirty or corrosive processes at 1–30 mbar — distillation, deodorisation, steel degassing, drying. The liquid ring pump's 33 mbar ultimate becomes a 1–3 mbar set ultimate, and the liquid ring tolerates whatever the booster delivers. A gas-cooled booster (a share of the exhaust gas is cooled and bled back into the rotor chamber) allows the large differential this pairing needs; a standard booster is limited to about a 10 : 1 pressure ratio across itself.

Booster + dry screw (MB + DSI). The modern dry set: oil-free throughout, reaches 10⁻³ mbar, handles solvents and dust, no seal water. Coating, solar, battery, semiconductor roughing.

Two boosters in series on a backing pump for 10⁻⁴ mbar at very high speed — a 3,000 m³/h booster feeding a 600 m³/h booster feeding a 150 m³/h pump — used in furnaces and metallurgy.

4. A worked furnace

A vacuum heat-treatment furnace: chamber 6 m³, must reach 5 × 10⁻² mbar in 20 minutes from atmosphere, then hold 10⁻² mbar during the cycle against an outgassing load of 2 mbar·m³/h from the charge.

Backing pump alone. To 50 mbar in the first 5 minutes needs (6/0.083) × ln(1,013/50) = 72 × 3 ≈ 220 m³/h → a V301 (300 m³/h) with margin. From 50 mbar to 5 × 10⁻² mbar is three decades; at 300 m³/h nominal, falling to perhaps 150 m³/h near 0.1 mbar, that is 6 × 6.9 / ~220 average ≈ 11 minutes — total 16 minutes, just inside 20, with no margin and the knee working against us. Holding 10⁻² mbar against 2 mbar·m³/h needs S = Q/p = 200 m³/h at 10⁻² mbar, which a single-stage vane pump does not have there.

With an MB600 booster cutting in at 50 mbar: effective speed 1,400–1,700 m³/h through the band from 10 to 0.1 mbar; the three decades take about 2 minutes instead of 11, and holding 10⁻² mbar against 2 mbar·m³/h is trivial (the set has ~1,200 m³/h there). Pump-down 7–8 minutes, hold pressure with margin, and the furnace can take a heavier or wetter charge. The booster's 7.5 kW runs only below 50 mbar.

The set: MB600 on a V301, staging 6.7 : 1, pressure-switch cut-in at 50 mbar, inlet filter and anti-suckback valve on the V301. For the same furnace with carburising gas or quench oil vapour, the backing pump becomes a DSI300.

5. Running a booster for twenty years

  • Temperature. The booster is limited by rotor expansion; most allow 100–120 °C discharge. Monitor the exhaust temperature and interlock. Gas-cooled designs for continuous high-differential duty.
  • Oil. Gear and bearing chambers are oil-lubricated and sealed from the gas; check levels and change on hours. Oil in the gas chamber means a seal has failed.
  • Direction and clearances. A booster reversed by a mis-wired motor will run and pump the wrong way, pressurising the chamber. Check rotation at commissioning.
  • Dust. The clearances are 0.1–0.3 mm; abrasive dust wears them and the compression ratio falls year by year. Filter upstream.
  • Standby. Two sets in a lead/lag arrangement for continuous processes; a bypass line around the booster so the backing pump alone can hold a degraded vacuum during a booster change.

Recommended Dr.Vakuum machines

Mechanical boosters (MB Series) — 280 to 4,140 m³/h at 50 Hz:

Model Displacement, 50 Hz Motor Backing pump for a 5–8 : 1 set
MB70 280 m³/h 0.75 kW V40, DV60
MB150 500 m³/h 2.2 kW V63, V100, DV90
MB300 1,000 m³/h 3.7 kW V140, DV175, DSI150
MB600 2,000 m³/h 7.5 kW V301, DSI300, LT200-170
MB1200 4,140 m³/h 11 kW V630, DSI630, LT380-320
MB4200 — — Large furnace and metallurgy sets; sized per enquiry

The booster is also the inlet stage of the dry-condensing vacuum sets in palm oil deodorisation and the fast-roughing option for coating and analytical systems.

Set sizing. Send us the chamber volume, the target pressure and time, the process gas load and what is in it, and we will size the booster and backing pump as a pair, with the cut-in pressure and staging ratio shown. Talk to an engineer.