Egg, dairy and liquid food: vacuum evaporation and concentration

7 Min. Lesezeit

Sweetened condensed milk, evaporated milk, coconut cream and milk powder, pineapple and passion-fruit concentrate, tomato paste, liquid egg for the bakery trade — Thailand makes all of them in large volumes, and every one passes through an evaporator that removes most of the product's water by boiling it under vacuum. The vacuum is what makes the process possible: at 60–250 mbar absolute, water boils at 36–65 °C, below the temperatures at which milk proteins denature, egg coagulates (60 °C), and fruit flavours and colour are lost. The pump that maintains that vacuum is a small part of the plant and a frequent cause of lost production when it is wrong.

1. How a food evaporator makes vacuum

As in a sugar mill, the vapour boiled off the product — tonnes per hour — does not go to a pump. It goes either to the heating side of the next effect (in a multiple-effect evaporator, where the vapour from effect 1 heats effect 2 at a lower pressure, and so on through 3–7 effects) or to a mechanical vapour recompressor (MVR — a fan or compressor that raises the vapour's pressure so it can heat its own evaporator), and finally the last effect's vapour goes to a condenser.

The vacuum pump removes only what the condenser cannot condense:

  • Air dissolved in the feed — milk and juice are air-saturated; about 15–25 L of air per tonne of feed.
  • Air leakage through the evaporator's many flanges, sight glasses, pump seals and CIP connections. The dominant term in a plant of any age: 10–40 kg/h on a large multi-effect unit.
  • Non-condensable gases from the product — CO₂ from fruit juices, volatile aromas (which in juice evaporators are recovered by a separate aroma-stripping condenser before the main condenser).
  • Water vapour that passes the condenser, saturated at the condenser's outlet temperature.

The last term is what makes the pump size depend so strongly on the cooling water, and it is worth taking slowly.

Why does a 32 °C cooling tower double the size of the pump?

The condenser cools the vapour to a few degrees above the cooling water temperature. The gas leaving it is air saturated with water vapour at that temperature, and the fraction of the gas that is vapour is the vapour pressure at that temperature divided by the condenser pressure. For a last effect at 80 mbar:

Cooling water in Condenser outlet gas Vapour pressure Vapour fraction Gas volume per Nm³ of air
18 °C (European winter) 25 °C 32 mbar 40 % 21 m³
28 °C (Thai cool season) 35 °C 56 mbar 70 % 42 m³
32 °C (Thai hot season) 38 °C 66 mbar 83 % 74 m³

The same 30 Nm³/h of air load becomes 630 m³/h of pump inlet volume in Europe and 2,200 m³/h in a Thai April. Evaporators imported with a pump sized on the manufacturer's home climate fall short of vacuum exactly when the plant is running hardest. The remedies, in order of cost: a cold sub-cooler (a small chilled-water after-condenser that brings the gas to 15 °C before the pump — removes most of the vapour for a few kW of refrigeration), a larger pump sized on the 32 °C case, or chilled seal water on a liquid ring pump so its own ultimate stays low.

2. Pressure levels and products

Product Evaporator type Last-effect pressure Boiling temp Notes
Skim / whole milk to 50 % TS (for powder) Falling film, 3–7 effects or MVR 60–100 mbar 36–45 °C Largest units; MVR with a liquid ring on the condenser
Sweetened condensed milk Falling film + finisher 100–200 mbar 45–60 °C High viscosity in the finisher; forced circulation
Evaporated milk Falling film 100–150 mbar 45–55 °C Fouling by protein; CIP daily
Coconut cream / milk Falling film or plate 80–150 mbar 40–55 °C Fat carry-over to the condenser
Fruit juice to 65 °Brix Falling film, aroma recovery 60–100 mbar 36–45 °C Aroma stripper before main condenser
Tomato paste to 30 °Brix Forced circulation, 2–3 effects 60–120 mbar 36–50 °C Foam and fibre; large separators
Liquid egg (pre-concentration) Plate or falling film 60–80 mbar 36–40 °C Must stay below 55 °C; foam
Whey, permeate Falling film, MVR 60–100 mbar 36–45 °C Lactose crystallisation downstream

In every case the deepest pressure is 60 mbar — above a liquid ring pump's 33 mbar ultimate with cool seal water, which is why liquid ring pumps serve almost every food evaporator, and below it with warm seal water, which is why they must be run chilled or oversized.

3. Sizing a dairy evaporator's pump

A 10 t/h feed, 4-effect falling-film milk evaporator concentrating skim milk from 9 to 48 % total solids (evaporating 8.1 t/h of water), last effect at 70 mbar, condenser on 30 °C cooling tower water (outlet gas 37 °C, vapour pressure 63 mbar).

  • Dissolved air: 10 t/h × 20 L/t = 0.2 Nm³/h — negligible.
  • Leakage: a modern, well-maintained plant of this size, 10 kg/h ≈ 8 Nm³/h. (An old plant: three times this.)
  • Total non-condensables ≈ 8–9 Nm³/h.
  • Vapour fraction at 70 mbar, 37 °C: 63/70 = 90 % — the gas is nine parts vapour to one part air.
  • Inlet volume: 8.5 × (1,013/70) × (310/273) × (70/7) ≈ 1,400 m³/h at 70 mbar.

Without a sub-cooler, that is an LS410-320 (1,400 m³/h nominal) running with 15 °C chilled seal water to hold its capacity at 70 mbar — a 37 kW pump to remove 10 kg/h of air. With a chilled-water sub-cooler bringing the gas to 15 °C (17 mbar vapour pressure, 24 % vapour fraction), the inlet volume falls to about 170 m³/h, and an LM230-120 (230 m³/h, 5.5 kW) does the job with margin. The sub-cooler costs about 10 kW of refrigeration; the saving is 30 kW of pump power for the life of the plant. This is the single most valuable change on an imported evaporator in Thailand.

For MVR evaporators the pump duty is the same in kind and smaller in size: the compressor handles the vapour, the condenser is small, and the pump sees leakage air plus a little vapour — typically LM145-080 to LM200-065 class.

4. Carry-over, foam and CIP

Milk, egg and juice foam; coconut cream carries fat; tomato carries fibre. All of it reaches the condenser when a level control fails or a feed surge hits a separator, and from the condenser it reaches the pump.

  • Separators on every effect, sized for the vapour velocity; anti-foam dosing on egg and whey.
  • A knock-out pot with a sight glass between condenser and pump, drained to the product recovery tank (what collects there is product and water, not waste).
  • Stainless steel liquid ring pumps — milk condensate is slightly acidic, fruit condensate more so, and chlorinated CIP will reach the pump's inlet line.
  • The pump's seal water loop on a separate circuit from the product side; a plate heat exchanger against the plant's chilled water; make-up from treated water. Sweet-smelling seal water means a condenser is passing product; investigate.
  • CIP: the vacuum line to the pump isolated by an automatic valve during CIP; the knock-out pot included in the CIP circuit (spray ball); the pump itself flushed with clean water on shutdown.

5. Worked plants

Plant Evaporation Last effect Non-condensables Dr.Vakuum answer
Coconut cream, 2 t/h feed, 2-effect 1.2 t/h 120 mbar ~3 Nm³/h LM200-065 + knock-out pot
Fruit juice, 5 t/h, 3-effect with aroma recovery 3.8 t/h 70 mbar ~5 Nm³/h LM270-155 with chilled seal water, or LM200-065 + sub-cooler
Skim milk, 10 t/h, 4-effect (above) 8.1 t/h 70 mbar ~9 Nm³/h LM230-120 + sub-cooler; or LS410-320 chilled
Milk for powder, 30 t/h, MVR + 2-effect finisher 26 t/h 60 mbar ~15 Nm³/h LT250-200 two-stage, chilled, + sub-cooler
Tomato paste, 20 t/h, 3-effect forced circulation 15 t/h 80 mbar ~25 Nm³/h (old plant) LS410-320 + sub-cooler, stainless, large knock-out

Recommended Dr.Vakuum machines

Liquid ring monobloc (LM Series), stainless — small and medium evaporators, and any evaporator with a sub-cooler: LM145-080 (80 m³/h), LM200-065 (105 m³/h), LM230-120 (230 m³/h), LM270-155 (375 m³/h).

Liquid ring single-stage (LS Series) — large evaporators sized on the hot-season case: LS275-220, LS410-320.

Two-stage liquid ring (LT Series) — last effects at 60 mbar with warm seal water: LT230-160V, LT250-200.

The condenser-and-pump arithmetic in §1 is the same one worked for dryers in Inlet filtration, condensers and knock-out pots.

Evaporator audit. Send us the last-effect pressure, the cooling water temperature in April, and the pump you have, and we will show what a sub-cooler or chilled seal water would do to the vacuum and the power. Talk to an engineer.