Vacuum sewerage and lift stations: moving wastewater where gravity cannot

7 Min. Lesezeit

Pattaya, Phuket, Hua Hin, the Chao Phraya delta, every island resort and most new housing estates on the central plain share a problem with sewerage: the ground is flat, the water table is a metre down, and a conventional gravity sewer needs a trench that gets deeper with every hundred metres until a pump station lifts the flow back up — in soil that collapses and fills with water as it is dug. Vacuum sewerage solves it the other way round. The sewer is a network of small (90–250 mm) plastic pipes laid shallow in a saw-tooth profile, and the whole network is held under vacuum by one vacuum station. Wastewater from each house collects in a chamber; when enough has gathered, an interface valve opens for a few seconds and the vacuum pulls the slug of sewage, followed by a gulp of air, into the pipe and along toward the station. No pump stations in the street, no deep trenches, no infiltration, and a single building to maintain.

1. How the network moves sewage with air

The interface valve is the key. It admits roughly two to twelve volumes of air for every volume of sewage (the air-to-liquid ratio, set by how long the valve stays open after the chamber empties). The air is what moves the liquid: the pressure difference between atmosphere behind the slug and the vacuum ahead of it accelerates the mixture to 5–6 m/s, the slug breaks up, and the air carries it as a spray and a stream along the pipe. At each lift (the saw-tooth's upward step, 0.3–1.5 m) the liquid pools until the next valve cycle's air pushes it over. The network therefore runs at −500 to −650 mbar at the station and no less than −250 mbar at the furthest valve (EN 1091 requires the vacuum at the valve to be adequate to operate it and move the slug).

Why does the air, not the sewage, size the vacuum pumps?

Because the vacuum pumps never pump sewage. The sewage arrives at the station's collection tank (a sealed vessel, 5–30 m³, under vacuum) and is pumped out of it to the treatment plant by ordinary sewage pumps. The vacuum pumps remove the air that came in with it — the two to twelve volumes per volume of liquid — plus the air that leaks into the network through valve seats and pipe joints, plus the air admitted when a valve is serviced. At an air-to-liquid ratio of 6 and a daily flow of 400 m³, the pumps remove 2,400 m³ of air a day at normal conditions — and they must remove it at −600 mbar, where its volume is 2.5 times larger. The station's design is therefore a calculation of the peak air inflow at the peak hour, at the station vacuum, with one pump out of service.

2. Sizing a vacuum station

A coastal housing estate: 800 connections, 3,200 people, 200 L/person/day → 640 m³/day, peak factor 2.5 → 67 m³/h at the peak hour. Air-to- liquid ratio 6 (a typical design value; higher on long flat networks), network leakage allowance 20 %.

  • Peak air at normal conditions: 67 × 6 × 1.2 ≈ 480 Nm³/h.
  • At −600 mbar (413 mbar absolute), the actual volume is 480 × 1,013/413 ≈ 1,180 m³/h at the pump inlet, saturated with water vapour (sewer air at 30 °C has a vapour pressure of 42 mbar — 10 % of the gas at this pressure) and carrying H₂S, odour and aerosol.
  • Duty/standby: EN 1091 and the common design guides require the station to meet peak with the largest pump out of service. Two pumps each of 1,200 m³/h at −600 mbar, or three of 600, with the control system running them by tank vacuum (start at −500 mbar, stop at −650) and rotating duty.
  • Collection tank: sized for 15–25 minutes of peak flow between sewage-pump starts, plus the air space that acts as the vacuum reservoir — 15–20 m³ for this station. The tank's air space damps the pumps' cycling; a station whose pumps start more than 6–8 times an hour has too small a tank.

A liquid ring pump's capacity at −600 mbar (413 mbar absolute) on warm seal water is about 60–65 % of its nominal, so 1,200 m³/h at −600 mbar calls for an LS410-320-class (1,400 m³/h nominal) pump, two of them. A dry alternative at this size is a Roots vacuum blower — the RBV150 (799–1,910 m³/h) — but see the next section on what the air carries.

3. Liquid ring or dry, on sewer air

Sewer air is saturated, warm, odorous, corrosive and occasionally wet — a slug that over-fills the collection tank, a foaming detergent discharge, a valve that sticks open and floods the line.

Liquid ring pumps (LM / LS Series) have been the vacuum-sewerage standard in Europe and Australia for forty years: they tolerate the wet, the ring water scrubs some of the H₂S and odour, a liquid carry-over passes through, and the discharge is cool and wet, which the odour-control unit prefers. Their needs: a closed-loop seal water system with a cooler (the station has mains water, so make-up is simple), stainless steel internals (sewer condensate is acidic from H₂S oxidation), and a seal water separator whose drain goes to the collection tank.

Dry claw and Roots blowers (CL, RBV) are used where water is scarce or the operator wants no seal water system: they need a knock-out pot with a level switch ahead of them, a coated or stainless gas path, and they discharge hot, dry, odorous air to the odour control. The RBV's −490 mbar maximum differential makes it suitable for networks designed at −450 to −500 mbar; the claw's 150 mbar ultimate (−860 mbar) covers any station. Many Thai stations built since 2015 use claw pumps for the low maintenance, with a liquid ring unit as a third, "dirty" standby.

4. The station building

  • Collection tank in stainless or coated steel, sealed, with level transmitters (sewage pumps start/stop), vacuum transmitter (vacuum pumps start/stop), an emergency high-level float that stops the vacuum pumps before sewage reaches them, and an inspection manway.
  • Sewage pumps (duty/standby) drawing from the tank under vacuum — they need the NPSH to pull against −600 mbar, so they sit low, or a pressure-compensation valve equalises the tank before they start.
  • Vacuum pumps duty/standby/assist, on anti-vibration mounts, in a separate ventilated room from the tank room.
  • Odour control on the vacuum pump exhaust: an activated carbon or biofilter unit; the exhaust is the station's only air outlet and the neighbours notice it.
  • Standby power: a generator or an automatic transfer switch — a vacuum network that loses vacuum for more than a few hours lets the collection chambers fill and the houses back up.
  • Monitoring: the vacuum level trend is the network's health — a slow fall with the pumps running longer each day is a leaking valve or joint, found by walking the network with the valve monitors or by isolating branches.

5. Related: lift stations and vacuum priming

Conventional gravity systems still need lift stations, and vacuum appears there in two small duties:

  • Vacuum priming of dry-pit sewage pumps and siphons: a small liquid ring pump (LM120-030, 30 m³/h) with a priming tank evacuates the pump casing and suction pipe before the pump starts. Intermittent, wet, simple.
  • Vacuum-assisted sewer cleaning (jet-vac trucks) — a Roots or liquid ring unit on a truck pulling debris from manholes into a tank: the RBV Series in mobile form, with a cyclone, at −500 mbar and 1,500–3,000 m³/h.

6. Worked stations

Station Connections Peak air at station vacuum Dr.Vakuum answer
Island resort, 60 villas 60 ~120 m³/h at −550 mbar 2 × LM200-065 (105 m³/h) + carbon filter
Housing estate, 300 connections 300 ~450 m³/h at −600 mbar 2 × LM270-155 (375 m³/h) or 2 × CL300 + knock-out
Coastal estate (above), 800 connections 800 ~1,200 m³/h at −600 mbar 2 × LS410-320, stainless, cooled seal loop
Town centre, 2,500 connections, long flat network 2,500 ~4,000 m³/h at −650 mbar 3 × LS520-400 (2,600 m³/h) duty/duty/standby
Dry-pit lift station priming — 30 m³/h intermittent LM120-030

Recommended Dr.Vakuum machines

Liquid ring (LM / LS Series), stainless, closed-loop seal water — the vacuum-station standard: LM200-065, LM270-155, LS275-220, LS410-320, LS520-400.

Dry claw (CL Series) — water-free stations with a knock-out pot: CL150, CL300.

Roots vacuum blowers (RBV Series) — networks designed at −450 to −500 mbar, and jet-vac trucks: RBV100, RBV150.

The treatment plant the station pumps to has its own blowers — see Aeration tank wastewater treatment with Roots blowers.

Network to station. Send us the connection count, the daily flow, the network length and the design vacuum, and we will return the peak air load, the pump schedule with standby, and the tank size. Talk to an engineer.