На производстве
Применения
Руководства по подбору и заметки по применению — как инженеры в упаковке, пищевой промышленности, фармацевтике, полупроводниках и тяжёлой промышленности подбирают насосы и воздуходувки Dr.Vakuum, с расчётами.
Solar PV module lamination: the vacuum laminator that decides a 25-year warranty
Every crystalline-silicon solar module is made in a vacuum laminator — glass, encapsulant, cells, encapsulant, backsheet, pulled down under a membrane at 1–5 mbar and heated to 150 °C so the EVA or POE flows and cross-links with no bubbles. A bubble is a delamination and a hot spot in year five. Thailand's module plants run laminators by the dozen on 24-hour cycles; this note covers the pump-down that sets the cycle, the encapsulant vapour that kills pumps, multi-stage laminators, and the Dr.Vakuum V, DV and DSI machines for a 500 MW line.
Semiconductor back-end (OSAT): die attach, transfer moulding and wafer handling
Thailand's semiconductor industry is the back end — the assembly and test plants that take finished wafers and turn them into packaged chips. Vacuum handles the wafer on the dicing saw and the die on the bonder collet, pulls the voids out of the mould compound and the underfill, dries the parts before moulding and holds the strips on every stage. Shallow, clean, fast and continuous, with a few deep process steps — and the Dr.Vakuum DRV, CL and DSI pumps that serve them from the subfab.
Hard-disk drive and precision electronics manufacturing: vacuum in the cleanroom
Thailand builds a third of the world's hard-disk drives, and a drive is assembled in a Class 100 cleanroom by machines that handle a 95 mm platter and a 2 mm slider by suction, laminate and bond under vacuum, and test in helium-filled and evacuated enclosures. Why every vacuum generator near the product must be oil-free and particle-free, the pick-and-place and chucking duties, vacuum degassing of adhesives and lubricants, media sputtering, and the Dr.Vakuum DRV, DSI and T machines that serve a cleanroom from outside its wall.
HVAC and refrigeration: system evacuation and dehydration before charging
A refrigeration circuit with a few hundred ppm of moisture in it forms acid, freezes at the expansion valve and kills the compressor. Evacuating to 500 microns (0.67 mbar) before charging is how the moisture is removed — and on a 2 MW chiller plant or an air-conditioner factory line, that is a serious vacuum duty, not a hand pump. Why the target is a pressure and a rise test rather than a time, the two-stage pump that reaches it, large-system and production-line sizing, and the oil and refrigerant that reach the pump.
Battery manufacturing: electrode drying, electrolyte filling and degassing
A lithium-ion cell plant uses vacuum at four points that decide the cell's life — drying the electrode coils and the assembled cell to parts-per-million moisture, filling the electrolyte into a cell whose pores would otherwise trap air, degassing after formation, and sealing. NMP and electrolyte solvent vapour in the pump, the dry-room constraint, and why the plants being built in Thailand's EV corridor specify dry screw pumps and nothing else.
PVD coating and metallising: from rough vacuum to high vacuum in one cycle
A decorative chrome-look on a tap, a titanium nitride edge on a drill, an aluminium mirror inside a headlamp and the metallised film in a snack bag are all made by evaporating or sputtering metal in a chamber at 10⁻³ to 10⁻⁵ mbar. Every cycle crosses four decades of pressure, and each decade wants a different pump. Rough, fine and high-vacuum stages, batch coaters versus roll-to-roll metallisers, water vapour as the enemy, and the Dr.Vakuum set for a 2 m³ sputter chamber.
Transformer oil degassing and dehydration: the vacuum side of an oil treatment plant
An oil treatment plant sprays hot transformer oil into a vacuum chamber where dissolved water, air and gases flash out of a thin film — bringing moisture from 50 ppm to under 5 and gas content from 10 % to under 0.1 %. The degassing column pressure, the vapour and gas load, why a Roots booster on a two-stage pump is the standard set, oil carry-over and foaming, and sizing for 3,000 and 10,000 litre-per-hour plants.
Vacuum impregnation of castings, motor windings and transformers
Vacuum impregnation fills porosity in a die casting with sealant, saturates a motor winding with varnish, and dries and fills a transformer core with oil — by pulling the air out of the voids first so the liquid can get in. The dry-vacuum, wet-vacuum and pressure steps, why castings need 1–5 mbar and windings 50–100 mbar, resin and varnish vapour in the pump, and the Dr.Vakuum V and DV machines for an autoclave line.
Vacuum pick-and-place, lifting and robotic handling: flow, not depth
Suction cups hold with pressure difference but survive with flow — porous cartons, sheet steel and bagged product each leak differently, and the generator must keep up. Cup sizing with safety factors, porous versus non-porous grip, when a central blower beats point-of-use ejectors, and the Dr.Vakuum 1SC and CB machines that do it.
Vacuum lamination presses and vacuum reflow in PCB and SMT assembly
Multilayer lamination, solder-mask and dry-film vacuum laminators, and vacuum reflow for void-free solder joints — what pressure each needs, why ultimate matters for the press but speed matters for the laminator, and why pumps near a clean assembly line must be dry.
High vacuum for coating and analytical instruments: turbo, cryo and the backing pump
Below 10⁻³ mbar the pump set becomes a system — a turbomolecular or cryogenic high-vacuum pump that cannot exhaust to atmosphere, and a backing pump whose curve decides how well the turbo works. Compression ratio, foreline pressure, cryopump regeneration and sizing the forevacuum for a sputter coater or an electron microscope.