Instant noodle and dry pasta lines: vacuum mixing and vacuum drying
Thailand makes over three billion packs of instant noodles a year, and a growing share of them are non-fried, air- or vacuum-dried rather than deep-fried, for the health-conscious export market. Vacuum appears at both ends of these lines: in the dough mixer, where it changes the texture of the noodle, and in the dryer, where it lets the noodle dry at a temperature that keeps the starch from gelatinising twice. The pumps are different sizes, see different gases and are chosen differently.
1. Vacuum mixing: what it does to the dough
Noodle dough is stiff — 30–35 % water on flour for instant noodles, 28–32 % for dry pasta — and mixed for only 10–20 minutes. At that hydration the water does not reach every starch granule and gluten strand; air folded in during mixing leaves micro-bubbles in the sheet that become white specks and weak points after frying or drying.
Mixing under vacuum at 100–300 mbar absolute:
- Removes the entrained air, so the dough sheet is denser and the noodle is translucent, with a smoother surface and a firmer, more elastic bite — the "al dente" of a pasta and the chew of a Japanese-style ramen.
- Accelerates hydration: with no air in the voids, water wets the flour faster and the gluten network develops in a shorter mix.
- Allows lower water addition for the same workability, which means less to dry later — a direct energy saving on a non-fried line.
- Reduces oxidation of the flour's carotenoids, so pasta keeps a yellower colour.
Nearly all pasta presses and most modern noodle lines mix under vacuum either in the main mixer or in a vacuum pre-mixer / extruder feed chamber just before the sheeting rolls or the die.
Why does the mixer pump see flour, and what does that mean?
Because the mixer bowl is a cloud of flour for the first minute of every batch, and the vacuum is often applied while the bowl is still dusty. Flour is fine (20–100 µm), hygroscopic and — in a pump — a paste-former: flour plus the moisture in the air plus a warm pump casing makes dough inside the pump. An oil-sealed pump makes a flour-oil paste that destroys the vanes; a dry vane pump packs flour into the vane slots. The answer is a cyclone and a cartridge filter at the mixer outlet, with a differential gauge, and applying vacuum only after the dry ingredients have wetted (most mixer controls sequence this). With that protection a dry-running pump lasts; without it nothing does. Flour dust is also explosible — the filter housing is earthed and vented.
2. Sizing the mixer pump
The mixer is a batch chamber: a 300–600 L bowl (half full of dough) pulled from atmosphere to 150 mbar in 30–60 seconds at the start of the vacuum phase, then held against leakage through the shaft seals and the lid gasket. A 500 L bowl with 250 L of headspace to 150 mbar in 45 seconds:
S_eff = (0.25 / 45 s) × ln(1,013 / 150) × 3,600 = 0.0056 × 1.91 × 3,600 ≈ 38 m³/h
A DRV40 (48 m³/h, oil-free, 90 mbar ultimate) does it; for a twin-shaft 1,000 L mixer on a 20 t/day line, a DRV100. The 90 mbar ultimate suits the duty — mixers rarely go below 100 mbar, since deeper vacuum draws moisture out of the dough and stiffens it. Where a line specifies 50–80 mbar for a particular product, a dry claw CL80 or CL300 (50 mbar ultimate) takes over.
Pasta presses with a continuous vacuum chamber between mixer and extrusion screw run the pump continuously against the leakage of the dough-sealed screw — small flow (10–30 m³/h), continuous, dusty: a DRV25 with the same filtration.
3. Vacuum drying of non-fried noodles and pasta
Conventional pasta drying takes 4–12 hours of carefully humidified hot air so the outside does not dry faster than the inside and crack (case-hardening or "checking"). Non-fried instant noodles are dried in 30–60 minutes of hot air at 70–90 °C, which gelatinises and then retrogrades the starch and can leave a dense, slow-rehydrating noodle.
Vacuum drying at 30–60 mbar lets water evaporate at 25–35 °C. The product temperature stays low, moisture migrates outward evenly because the whole strand is at the boiling point, and the noodle stays porous — which is exactly the rehydration structure a cup noodle needs. Cycle times fall to 20–40 minutes for noodle blocks; pasta takes longer but dries without checking. Vacuum microwave drying combines the two for the fastest cycles.
The duty is continuous evaporation, sized by the water load, with a condenser doing most of the work:
- A 20 t/day non-fried noodle line dries steamed noodle blocks from ~35 % to 10 % moisture: about 7 tonnes of water a day, 300 kg/h over a 24-hour run.
- At 50 mbar and a product temperature of 33 °C, 300 kg/h of vapour is about 9,000 m³/h — far beyond any pump. A refrigerated or chilled-water condenser at 5–10 °C (vapour pressure 9–12 mbar) removes 80–85 % of it; the pump handles the remainder plus air leakage.
- Pump duty: ~50 kg/h of residual vapour plus ~15 kg/h of air in-leakage on a large dryer at 50 mbar → roughly 1,800 m³/h of actual volume. A liquid ring pump with chilled seal water — the LS410-320 at 1,400 m³/h nominal on 15 °C water delivers about this at 50 mbar — or a Roots booster on a smaller liquid ring pump (MB600 on an LT230-160V).
For a batch vacuum dryer (a 2–4 m³ chamber of trays, common on pasta and specialty noodle lines), the pump-down of the chamber adds a short-cycle requirement — 4 m³ to 50 mbar in 5 minutes needs about 150 m³/h — and the holding duty against the condenser's residual is smaller. An LM270-155 (375 m³/h) with a chilled condenser does both.
4. Oil-free where it matters
The mixer and the pasta press are open to the product: the pump inlet is a few centimetres from the dough. Dry pumps only. The dryer pump is downstream of a condenser and never shares an atmosphere with the noodle; liquid ring (water) is the natural choice and oil-sealed is acceptable with the usual ballast and exhaust precautions. Many plants, having standardised on dry pumps for the mixers, use a DSI Series dry screw on a small batch dryer too, for a single oil-free plant room.
5. A worked 20 t/day non-fried line
| Duty | Pressure | Cycle / load | Dr.Vakuum answer |
|---|---|---|---|
| Twin-shaft vacuum mixer, 1,000 L | 150 mbar | 500 L headspace in 45 s | DRV100 + cyclone + cartridge filter |
| Extruder feed vacuum chamber | 100 mbar | continuous, 20 m³/h | DRV25 + filter |
| Continuous vacuum dryer | 50 mbar | 300 kg/h water, condenser at 8 °C | LS410-320 with chilled seal water, or MB600 + LT230-160V |
| Pilot batch dryer, 2 m³ | 40 mbar | 50 mbar in 4 min; 30 kg/h water | LM270-155 + condenser |
Recommended Dr.Vakuum machines
Dry rotary vane (DRV Series) — vacuum mixers and press chambers, oil-free, 90 mbar ultimate: DRV25, DRV40, DRV60, DRV100.
Dry claw (CL Series) — mixers specified below 90 mbar: CL80, CL300.
Liquid ring (LM / LT / LS Series) — vacuum dryers behind a condenser: LM270-155, LT230-160V, LS410-320.
Roots boosters (MB Series) — large continuous dryers at 30–50 mbar: MB600.
The condenser arithmetic that makes the dryer pump a tenth of its naive size is worked through in Inlet filtration, condensers and knock-out pots.
Line to pumps. Tell us the mixer volume and cycle, and the dryer's water load and pressure, and we will size the mixer pump with its dust protection and the dryer condenser and pump as a pair. Talk to an engineer.