Technische Daten

Duty
Pressure
Nominal Speed 50 Hz
0.99–2.92 m³/min (59–175 m³/h)
Max Pressure 50 Hz
8000 mmAq (78.5 kPa)
Motor Power 50 Hz
up to 5.64 kW
Speed Range
850–1750 rpm
Sauganschluss
50 mm (2 inch)
Kennlinie 50 Hz, at each model's base speed. Solid = RB pressure duty; dashed = RBV vacuum duty (pressure as magnitude).
100200300400500600110100STATIC PRESSURE · mbar →CAPACITY (SUCTION) · m³/min ↑RB400RBV400RB350RBV350RB300ARBV300ARB300RBV300RB200ARB250RBV200ARBV250RB250ARBV250ARB200RBV200RB150RBV150RB125RBV125RB125SRBV125SRB100RBV100RB080RBV080RB065RB040RBV040RB050RBV050
Kennlinie der RB-Serie ansehen

Replaces

RB050 is a direct alternative to the following competitor models.

6 matches
  • Howden Roots Independent · US
    URAI 24U
    Why is this an equivalent?

    1.5in-class frame, 2in NPT, to 143 cfm.

    Close match
  • Gardner Denver Ingersoll Rand · US
    Sutorbilt Legend 2L
    Why is this an equivalent?

    2in gear frame, 2in screwed port.

    Close match
  • Robuschi Ingersoll Rand · IT
    RBS 15
    Why is this an equivalent?

    Tri-lobe, 2in ANSI flange, 31-162 cfm at 4 psi.

    Close match
  • Howden Roots Independent · US
    URAI 33U
    Why is this an equivalent?

    2in NPT, to 186 cfm at 12 psi.

    Approximate
  • Aerzen Independent · DE
    Delta Blower GM 3 S
    Why is this an equivalent?

    DN 50. 240 m3/h (4.0 m3/min). Smallest frame in the range.

    Close match
  • Kaeser Independent · DE
    OMEGA 21P
    Why is this an equivalent?

    DN 50. 176 cfm (5.0 m3/min). Smallest block in the range.

    Approximate

Howden Roots + Aerzen + Kaeser are both Independent brands.· Gardner Denver + Robuschi are both Ingersoll Rand brands.