RBV200 RB-Serie Dry
Dr.Vakuum RBV200
Photo
Photo
Photo
Photo
Technical specifications
- Duty
- Vacuum
- Nominal Speed 50 Hz
- 17.01–51.03 m³/min (1021–3062 m³/h)
- Max Pressure 50 Hz
- -5000 mmAq (-49.0 kPa)
- Motor Power 50 Hz
- up to 51.28 kW
- Speed Range
- 600–1500 rpm
- Inlet connection
- 200 mm (8 inch)
Replaces
RBV200 is a direct alternative to the following competitor models.
7
matches
- Howden Roots Independent · USRAM-DVJ 616J8in flange inlet, 945 cfm at 12 inHg, to 27 inHg.
Why is this an equivalent?
8in flange inlet, 945 cfm at 12 inHg, to 27 inHg.
Exact match - Howden Roots Independent · USRAM-VJ 616JWater-sealed vacuum variant, to 24 inHg.
Why is this an equivalent?
Water-sealed vacuum variant, to 24 inHg.
Close match - Gardner Denver Ingersoll Rand · USDuroFlow 701270 Series, 8in flange, 853-1762 cfm at 4 psi. Pressure-duty frame; confirm vacuum rating.
Why is this an equivalent?
70 Series, 8in flange, 853-1762 cfm at 4 psi. Pressure-duty frame; confirm vacuum rating.
Approximate - Howden Roots Independent · USURAI 718U8in flange, to 2280 cfm at 6 psi. Pressure-duty frame; confirm vacuum rating.
Why is this an equivalent?
8in flange, to 2280 cfm at 6 psi. Pressure-duty frame; confirm vacuum rating.
Approximate - Howden Roots Independent · USRAM 616Heavy-duty, 8in flange, to 2115 cfm at 12 psi. Pressure-duty frame; confirm vacuum rating.
Why is this an equivalent?
Heavy-duty, 8in flange, to 2115 cfm at 12 psi. Pressure-duty frame; confirm vacuum rating.
Approximate - Aerzen Independent · DEDelta Blower GM 50 LDN 200. 3288 m3/h (54.8 m3/min) vs our 51.03. Pressure-duty frame; confirm vacuum rating.
Why is this an equivalent?
DN 200. 3288 m3/h (54.8 m3/min) vs our 51.03. Pressure-duty frame; confirm vacuum rating.
Approximate - Kaeser Independent · DEOMEGA 62PDN 200. 1469 cfm (41.6 m3/min) vs our 51.03. Pressure-duty frame; confirm vacuum rating.
Why is this an equivalent?
DN 200. 1469 cfm (41.6 m3/min) vs our 51.03. Pressure-duty frame; confirm vacuum rating.
Approximate