Im Einsatz
Anwendungen
Auslegungshilfen und Anwendungsberichte — wie Anlageningenieure in Verpackung, Lebensmittel, Pharma, Halbleiter und Schwerindustrie Dr.Vakuum-Pumpen und Gebläse spezifizieren, mit vorgerechneter Auslegung.
Energy: VSD, central versus point-of-use, and the cost of oversizing a vacuum pump
A vacuum pump runs five thousand hours a year, and its electricity costs more than its purchase price within two to four years. Where the energy goes in each technology, why a pump sized for the worst case wastes power every other hour, what a variable-speed drive actually saves on a vane pump, a screw pump and a blower, when a central system beats twenty machines and when it does not, and a worked comparison for an injection-moulding hall at Thai tariffs.
Gas ballast, water vapour tolerance and why pumps drown
Every oil-sealed pump in Thailand pumps humid air, and most of them are running with the gas ballast closed. How vapour condenses inside the compression stage, what the ballast actually does, how to read the water vapour tolerance figure in kg/h, the warm-up and end-of-shift routines, and when a condenser or a different pump is the honest answer.
When a Roots booster pays: backing-pump combinations
A Roots booster multiplies a backing pump's speed by five to ten in the 0.01–10 mbar band and does nothing useful above it. Compression ratio and the 50 mbar switch-on, the overheating limit and bypass valves, booster-plus-liquid-ring and booster-plus-vane sets, and a worked furnace example.
Inlet filtration, condensers and knock-out pots: protecting the pump
Most vacuum pump failures are caused by what reached the inlet, and most of it could have been stopped a metre upstream. Sizing an inlet filter by face velocity and pressure drop, a knock-out pot by settling velocity, and a condenser by vapour load — with the rule that a condenser often buys a pump two sizes smaller.
Dry, oil-sealed or liquid ring: choosing a vacuum pump by what is in the gas
Pressure and flow narrow the choice to two or three technologies; what is in the gas decides between them. Water vapour, solvents, dust, oxygen, corrosives and particles — how each kills which pump, and a decision table that gets to a Dr.Vakuum series in three questions.
Reading a performance curve: pumping speed, ultimate pressure and the knee
A vacuum pump's curve says more than its datasheet. How to read speed against pressure on a log axis, what the knee tells you, why blower curves run the other way, how to find the operating point against a leak, and how to compare two machines honestly.
Vacuum pump or blower? Choosing by flow and depth, and the expensive mistake
Every vacuum duty sits somewhere on a map of flow against depth. Blowers own the top of it, pumps the bottom, and the overlap in the middle is where money is wasted. Where side channel ends and claw begins, mbar versus kPa versus mmAq, and a decision table with model codes.
How to size a vacuum pump: pump-down time, conductance and effective speed
The three numbers that size every vacuum pump — volume, target pressure and time — and the two corrections (ultimate pressure and pipe conductance) that explain why the pump you calculated is too small. Worked examples against Dr.Vakuum curves.