Auslegungshilfen und Anwendungsberichte — wie Anlageningenieure in Verpackung, Lebensmittel, Pharma, Halbleiter und Schwerindustrie Dr.Vakuum-Pumpen und Gebläse spezifizieren, mit vorgerechneter Auslegung.
Laboratory vacuum: rotary evaporators, filtration and central lab vacuum lines
A chemistry lab uses vacuum at three levels — 100–300 mbar for filtration and aspiration, 5–50 mbar for rotary evaporation, and below 1 mbar for drying and Schlenk work — and the water aspirator that once did the first two is being retired for water and cost reasons. Pumps per bench versus a central lab line, solvent vapour in oil-free and oil-sealed pumps, controllers and cold traps, and sizing for a 20-bench QC laboratory.
Dental and clinic suction systems: wet, dry and semi-dry, sized by chairs
A dental surgery's suction is a high-flow, low-vacuum duty with a wet, contaminated inlet, sized by the number of chairs in simultaneous use rather than by pump-down. Wet versus dry systems, amalgam separation, the 300 L/min-per-chair rule, central plants for polyclinics, and the dry pumps that have replaced water-ring units.
Hospital central medical vacuum to ISO 7396-1: sizing a duplex or triplex plant
How to size a medical vacuum plant from terminal units and diversity, why the standard demands duplex capacity with one pump out, bacterial filtration and drainage, alarms and standby, and why dry claw pumps have become the default in new hospitals.