Vacuum cooling of cooked rice, bakery and ready meals

7 min read

A central kitchen in Bangkok cooks several tonnes of rice a day for convenience stores. Cooked rice at 95 °C must reach 10 °C quickly — within two hours by the food-safety rules, within thirty minutes if the texture is to survive — and a blast chiller takes 90 minutes to cool a deep tray, from the outside in. A vacuum cooler does it in 10–20 minutes, from the inside out, because it does not cool the rice: it makes the rice cool itself.

1. The physics

Lower the pressure over hot, moist food and the water in it boils at the saturation temperature for that pressure: 100 °C at 1,013 mbar, 60 °C at 200 mbar, 30 °C at 42 mbar, 10 °C at 12 mbar, 2 °C at 7 mbar. Evaporating water takes about 2,400 kJ per kilogram from the food. Cooling 1 kg of rice (specific heat ~3.5 kJ/kg·K) by 85 °C needs about 300 kJ, so about 0.12 kg of water — 12 % by weight — must evaporate if all the cooling comes from evaporation. In practice the rule of thumb is 1 % weight loss per 6 °C of cooling for a product with free surface moisture.

That weight loss is the method's cost and its limit. For rice and bread, part of it is water that would be lost anyway in the chiller or is added back by misting; for a sauce-covered ready meal it must be managed by covering trays or adding water. Properties that make a product suitable: porous, moist, with surface area — rice, bread, steamed buns, noodles, cooked vegetables, lettuce. Dense, sealed or fatty products (a joint of meat, a sealed pouch) do not cool.

Why is the condenser, not the pump, the machine that matters?

Because of the vapour volume. Cooling a 500 kg batch of rice from 95 to 10 °C evaporates about 60 kg of water. At the end of the cycle the chamber is at 12 mbar, where one kilogram of water vapour occupies about 110 m³. If the pump had to remove that vapour directly, it would be handling several thousand cubic metres per hour at the end of the cycle — no pump of sane size does that. Instead a refrigerated condenser (cold trap) inside or beside the chamber, running at −5 to −15 °C, freezes the vapour onto its coils as it is produced, and the vacuum pump removes only the air — the chamber's initial fill plus leakage plus the air released from the food — and holds the pressure that the condenser needs. The condenser's refrigeration capacity sets the cooling rate; the pump sets how fast the cycle can start and how low it can finish.

2. The cycle

  1. Load trays of hot product (85–95 °C) into the chamber; door sealed.
  2. Pump-down of air: 1,013 mbar to the boiling point of the product at its current temperature (~700 mbar at 90 °C) in 1–2 minutes. Nothing cools yet. The pump does this alone.
  3. Flash cooling: the pressure falls as the pump removes air and the condenser removes vapour; the product temperature tracks the saturation temperature downward. Pressure control holds the rate so the product does not boil violently (rice grains burst; bread collapses) — typically a controlled ramp of 5–10 minutes down to about 40 mbar.
  4. Final cooling to 10 °C at 12 mbar, and often to 2–5 °C at 6–8 mbar for products that go straight to a chilled line. The pump must reach 6 mbar with the condenser's non-condensable load on it, which rules out liquid ring (33 mbar) and dry vane (90 mbar) as the final-stage pump.
  5. Vent with filtered air; unload; defrost the condenser between batches (hot gas or electric), while the next batch loads.

Cycle time 15–25 minutes; a 500 kg chamber does 2–3 batches an hour.

3. Sizing

Condenser duty. 60 kg of water in a 12-minute cooling phase = 300 kg/h × 2,400 kJ/kg ≈ 200 kW of refrigeration at an evaporating temperature of about −10 °C. That is a substantial chiller — a 500 kg rice cooler is a 60–80 kW compressor set — and it is the machine's main cost.

Pump, pump-down phase. Chamber 6 m³ (trolley loaded) from 1,013 to 700 mbar in 90 seconds, then to 40 mbar over the controlled ramp:

S = (6 / 0.025 h) × ln(1,013 / 40) = 240 × 3.2 ≈ 780 m³/h for a 90-second pump-down all the way to 40 mbar — faster than needed, since the ramp is controlled. Sizing on the initial air removal (1,013 → 700 mbar in 90 s) gives 240 × 0.37 ≈ 90 m³/h — too slow for the rest of the cycle. Machine builders settle at 300–600 m³/h for a 500 kg chamber, which pumps the air down in 2–3 minutes and leaves the controlled ramp to the pressure control valve.

Pump, holding phase. Non-condensables at the end of the cycle: air leakage into a large door-sealed chamber (5–20 m³/h at atmospheric equivalent for a food-grade vessel), air from the product (rice holds little; bread more), and vapour that escapes the condenser (the gas leaving a −10 °C condenser is saturated at 2.6 mbar — at a 6 mbar chamber pressure that is 40 % of the gas by volume). Perhaps 15 m³/h of free air equivalent → at 6 mbar that is 2,500 m³/h of actual volume to hold 6 mbar. So the holding duty, not the pump-down, sizes the pump at the deep end — and this is exactly where a Roots booster pays: a booster of 1,000–2,000 m³/h ahead of a 300 m³/h backing pump holds 6 mbar against that load.

The set for a 500 kg rice cooler: MB600 (2,000 m³/h) on a V301 (300 m³/h), with the V301 alone doing the early pump-down and the booster cutting in at 50 mbar. For a 150 kg bakery cooler: an MB150 on a V140. For a small 50 kg unit for a restaurant chain's kitchen: a V140 alone, accepting a slower final phase.

4. Oil-free and hygiene

The pump is downstream of the condenser and sees cold, mostly dry air with a little vapour; it is not in contact with product. An oil-sealed pump is therefore acceptable and standard, provided:

  • The gas ballast is open — the residual vapour is still there.
  • A non-return valve at the pump and a vent valve on the chamber ensure that a pump stop cannot draw oil toward the chamber.
  • The exhaust is ducted out of the food room through a mist separator.

Plants with a strict no-oil policy specify a dry screw (DSI300, 0.05 mbar) as the backing pump; it reaches 6 mbar easily and tolerates the vapour. Liquid ring pumps appear on large vegetable coolers (lettuce, which cools to 2 °C at 7 mbar with a steam-jet or booster stage) because they handle the dirt and the water, but on cooked-food coolers the oil-sealed or dry screw set is the norm.

The chamber itself is stainless, washdown, with a filtered vent; the condenser's defrost water (which has touched food vapour) drains to the floor through an air break.

5. Products and settings

Product Load temp Target Final pressure Weight loss Notes
Cooked rice, trays 90–95 °C 10 °C 12 mbar 8–12 % Mist before loading; controlled ramp to avoid bursting
Bread, buns 95 °C core 30 °C 42 mbar 3–4 % Prevents collapse; crust crisper; 3-minute cycle
Steamed buns, noodles 90 °C 15 °C 17 mbar 6–8 % Cover to limit surface drying
Ready meals, sauced 85 °C 5 °C 9 mbar 5–8 % Trays lidded with vent holes; add water to sauce
Cooked vegetables 90 °C 5 °C 9 mbar 8–10 % Excellent colour retention
Lettuce, leafy veg (field) 25 °C 2 °C 7 mbar 2–3 % Pre-wetting; largest installed base worldwide

Recommended Dr.Vakuum machines

Chamber Air pump-down Final 6–12 mbar hold Set
50 kg kitchen unit 130 m³/h adequate alone V140
150 kg bakery / central kitchen 130 m³/h 500 m³/h booster MB150 + V140
500 kg rice / ready-meal chamber 300 m³/h 2,000 m³/h booster MB600 + V301 or + DSI300
1,500 kg double-trolley 640 m³/h 4,140 m³/h booster MB1200 + V630

How a booster multiplies the backing pump's speed in exactly this band is set out in When a Roots booster pays.

Batch to machine. Tell us the product, batch mass, loading temperature, target and cycle time, and we will size the condenser duty and the pump set together. Talk to an engineer.