Dr.Vakuum

In the field

Applications

Sizing guides and application notes — how plant engineers across packaging, food & beverage, pharma, semiconductor and heavy industry specify Dr.Vakuum pumps and blowers, with the arithmetic shown.

Solar PV module lamination: the vacuum laminator that decides a 25-year warranty
8 min read

Solar PV module lamination: the vacuum laminator that decides a 25-year warranty

Every crystalline-silicon solar module is made in a vacuum laminator — glass, encapsulant, cells, encapsulant, backsheet, pulled down under a membrane at 1–5 mbar and heated to 150 °C so the EVA or POE flows and cross-links with no bubbles. A bubble is a delamination and a hot spot in year five. Thailand's module plants run laminators by the dozen on 24-hour cycles; this note covers the pump-down that sets the cycle, the encapsulant vapour that kills pumps, multi-stage laminators, and the Dr.Vakuum V, DV and DSI machines for a 500 MW line.

ElectronicsUtilities & Energy
HVAC and refrigeration: system evacuation and dehydration before charging
7 min read

HVAC and refrigeration: system evacuation and dehydration before charging

A refrigeration circuit with a few hundred ppm of moisture in it forms acid, freezes at the expansion valve and kills the compressor. Evacuating to 500 microns (0.67 mbar) before charging is how the moisture is removed — and on a 2 MW chiller plant or an air-conditioner factory line, that is a serious vacuum duty, not a hand pump. Why the target is a pressure and a rise test rather than a time, the two-stage pump that reaches it, large-system and production-line sizing, and the oil and refrigerant that reach the pump.

ElectronicsUtilities & Energy
Vacuum sewerage and lift stations: moving wastewater where gravity cannot
7 min read

Vacuum sewerage and lift stations: moving wastewater where gravity cannot

In flat, low-lying or high-water-table ground — much of coastal Thailand, its islands and its new housing estates — a gravity sewer needs deep, expensive trenches and a pump station every few hundred metres. A vacuum sewer collects from hundreds of houses through small-bore pipes laid shallow, pulled by a single central vacuum station at −500 to −650 mbar. How the system works, why the air-to-liquid ratio sizes the pumps, liquid ring versus dry pumps on sewage air, the collection tank and odour control, and sizing a station for 800 connections.

Utilities & Energy
Central vacuum cleaning systems for plants and warehouses
7 min read

Central vacuum cleaning systems for plants and warehouses

A central vacuum cleaning system puts a hose inlet every 30 metres through a factory and a separator and blower in a plant room — so housekeeping of flour, sugar, cement, plastic pellets or wood dust happens without portable machines that blow fine dust back into the air. Sized by simultaneous operators, not floor area; the −200 to −400 mbar window; separator and filter design for explosible dusts; and the Dr.Vakuum 1SC, 2SC and RBV machines for two to twenty operators.

Food & BeveragePneumatic ConveyingUtilities & Energy
Boiler feedwater and membrane deaeration: removing oxygen before it removes the boiler
7 min read

Boiler feedwater and membrane deaeration: removing oxygen before it removes the boiler

Dissolved oxygen at 10 ppb pits a boiler tube; at 8 ppm it destroys a feedwater system in a season. Deaeration removes it by stripping — with steam in a tray or spray deaerator, or with vacuum through a hollow-fibre membrane contactor — and in both cases a vacuum pump removes the stripped gas. Vacuum deaerators, the membrane contactor's vacuum-plus-sweep-gas duty, dissolved CO₂ for water treatment and bottling, sizing from the water flow, and the Dr.Vakuum LM and LS pumps.

Food & BeverageUtilities & Energy
Power plant condenser air extraction: the vacuum that sets the turbine's output
8 min read

Power plant condenser air extraction: the vacuum that sets the turbine's output

A steam turbine exhausts into a condenser at 40–100 mbar, and every millibar the condenser pressure rises costs the plant output — about 0.3–0.5 % per 3 mbar. The condenser makes its own vacuum by condensing steam; the air-extraction system's job is to remove the air that leaks in before it blankets the tubes. Hogging and holding duties, the HEI method for air load, why two-stage liquid ring pumps with a pre-cooler or an ejector first stage are the standard, cooling-water temperature in Thailand, and sizing for a 100 MW biomass unit.

Utilities & Energy
Transformer oil degassing and dehydration: the vacuum side of an oil treatment plant
7 min read

Transformer oil degassing and dehydration: the vacuum side of an oil treatment plant

An oil treatment plant sprays hot transformer oil into a vacuum chamber where dissolved water, air and gases flash out of a thin film — bringing moisture from 50 ppm to under 5 and gas content from 10 % to under 0.1 %. The degassing column pressure, the vapour and gas load, why a Roots booster on a two-stage pump is the standard set, oil carry-over and foaming, and sizing for 3,000 and 10,000 litre-per-hour plants.

ElectronicsUtilities & Energy
Biogas and landfill gas handling: saturated, corrosive and variable
7 min read

Biogas and landfill gas handling: saturated, corrosive and variable

Biogas from a palm oil mill's effluent ponds, a cassava starch plant or a landfill arrives water-saturated, laced with hydrogen sulphide and changing in flow by the hour. Extraction under slight vacuum, boosting to an engine or upgrader, why liquid ring with closed-loop seal water fits, Roots blowers for the dry side, condensate and H₂S management, and ATEX.

Chemical ProcessUtilities & Energy