Sizing guides and application notes — how plant engineers across packaging, food & beverage, pharma, semiconductor and heavy industry specify Dr.Vakuum pumps and blowers, with the arithmetic shown.
Vacuum distillation, short-path evaporation and vacuum crystallisation
Lowering the pressure lowers the boiling point, and that single fact is behind essential oil rectification, fatty acid and glycerine distillation, solvent recovery columns, short-path molecular stills for vitamin E and CBD, and the vacuum crystallisers that make salt, MSG and citric acid. What each needs from the vacuum system, why the column's own vapour never reaches the pump, and how a booster-plus-liquid-ring set covers the 1–50 mbar band.
Vacuum drying ovens and tray dryers for pharma and chemicals
A vacuum tray dryer removes solvent and water from a wet cake at 30–60 °C, where an API or a fine chemical survives — if the pump can hold the pressure against the vapour load and survive what the vapour is. Drying curves, the condenser that does most of the work, solvent recovery, oil-free versus oil-sealed near a GMP suite, and sizing for a 24-tray dryer.
Biogas and landfill gas handling: saturated, corrosive and variable
Biogas from a palm oil mill's effluent ponds, a cassava starch plant or a landfill arrives water-saturated, laced with hydrogen sulphide and changing in flow by the hour. Extraction under slight vacuum, boosting to an engine or upgrader, why liquid ring with closed-loop seal water fits, Roots blowers for the dry side, condensate and H₂S management, and ATEX.
Deodorisation and bleaching vacuum in palm oil refining
A palm oil refinery's deodoriser runs at 2–5 mbar and 240–260 °C with stripping steam and fatty acid vapour in the gas; the bleacher at 50–100 mbar with bleaching-earth dust. Steam ejectors, liquid ring, and the dry-condensing hybrid that is replacing them — sized for a 1,000 t/d refinery.
Dry, oil-sealed or liquid ring: choosing a vacuum pump by what is in the gas
Pressure and flow narrow the choice to two or three technologies; what is in the gas decides between them. Water vapour, solvents, dust, oxygen, corrosives and particles — how each kills which pump, and a decision table that gets to a Dr.Vakuum series in three questions.
Sizing vacuum for solvent recovery
The pump is volumetric, the process makes solvent by mass, and converting between them shows why sizing on the air load fails by an order of magnitude. Condenser placement, the slip fraction, and the temperature class that catches people out.
Sizing Roots blowers for wastewater aeration
Aeration is 45-75% of plant electricity, and most of the waste is not in the blower. Discharge pressure, the fouling penalty that compounds, why a Roots blower has no surge mode, and the turndown gap that never appears on a datasheet.