Dr.Vakuum
All applications

Vacuum distillation, short-path evaporation and vacuum crystallisation

7 min read

A liquid boils when its vapour pressure equals the pressure above it. Lower the pressure and it boils cooler. Everything in this note — distilling fatty acids that would crack at 350 °C, separating a heat-sensitive flavour from its carrier, purifying a cannabinoid extract, growing salt crystals without a heater — follows from that one sentence, and the vacuum system's job is to hold a pressure chosen by the chemistry. The pressures run from 50 mbar down to 10⁻³ mbar, and the equipment changes at every decade.

1. Vacuum distillation columns: 10–200 mbar

A rectification column separates components by boiling point. Under vacuum the boiling points drop and, usefully, the differences between them often widen, so fewer trays are needed. Thai process plants run vacuum columns for:

  • Fatty acid fractionation (from palm and coconut oil splitting): 2–10 mbar at the top, 220–260 °C in the reboiler. At atmospheric pressure the acids would boil above 350 °C and decompose.
  • Glycerine distillation: 5–20 mbar, 160–180 °C.
  • Essential oil rectification (lemongrass, citronella, eucalyptus, kaffir lime): 10–50 mbar, to strip terpenes without cooking the oxygenated compounds that carry the aroma.
  • Solvent recovery columns (ethanol–water, acetone, IPA): 100–500 mbar to lower the reboiler temperature and allow low-pressure steam.
  • Biodiesel methyl ester distillation: 1–5 mbar.

Why does the column's vapour never reach the vacuum pump?

Because the column has its own condenser at the top, and that condenser handles the whole vapour flow — tonnes per hour — by turning it back into liquid (reflux and distillate). What leaves the condenser toward the vacuum system is only what will not condense at the condenser temperature: air leakage into a hot vessel with many flanges and pump glands, light ends that are gases at the condenser temperature (methanol vapour at 5 mbar and 30 °C does not condense; dissolved CO₂; cracking gases from fatty acids), and vapour of the distillate saturated at the condenser outlet. The pump is sized on that, and on the column pressure — not on the distillation rate. A 30 t/d fatty acid column may need a vacuum set of a few hundred m³/h nominal. What the pump must survive is the carry-over: fatty acids that solidify at 40 °C in the inlet line, methanol in the oil, acetic acid in the seal water.

Sizing. A fatty acid column at 5 mbar, condenser at 60 °C (the distillate solidifies lower), leakage 8 kg/h, cracking gases 2 kg/h, distillate vapour at the condenser outlet negligible (its vapour pressure at 60 °C is well under 1 mbar). Ten kg/h of gas at 5 mbar and 60 °C is roughly 8 Nm³/h × (1,013/5) × (333/273) ≈ 2,000 m³/h at 5 mbar. The classic answer is a Roots booster on a two-stage liquid ring pump: an MB600 (2,000 m³/h) at the inlet, compressing to 30–50 mbar, backed by an LT200-120 (155 m³/h) with seal water that absorbs the acid carry-over. A heated inlet line and a knock-out pot, and the set runs the campaign. Where seal water is unwelcome, the backing pump becomes a DSI150 dry screw with a heated inlet, and the fatty acid passes through hot to an exhaust trap.

Solvent recovery columns at 100–300 mbar are a simpler duty — a LM200-065 liquid ring pump with the solvent itself or chilled water as the ring liquid, or a V-series pump with a condenser and ballast where the solvent is not oil-soluble.

2. Short-path and wiped-film evaporation: 0.001–1 mbar

Some molecules cannot be distilled at any pressure a column can reach: vitamin E (tocopherols) from palm fatty acid distillate, monoglycerides, omega-3 ethyl esters from fish oil, cannabinoid distillate, high-boiling fragrance fixatives. They decompose before they boil at 1 mbar. A short-path (molecular) still solves it by making the distance from the evaporating surface to the condenser shorter than the mean free path of the molecule — a few centimetres — so each molecule that evaporates reaches the internal condenser without colliding with another. That requires 10⁻³ to 10⁻² mbar, and the feed must be degassed at 1–10 mbar first, usually in a wiped-film evaporator stage, or the dissolved gas would destroy the vacuum.

The vacuum system is therefore a two-level one:

  • Degasser / wiped-film stage at 1–10 mbar: a Roots booster on a backing pump — MB150 on a DV60, sized on the dissolved gas and light-end load, with a cold trap.
  • Short-path stage at 10⁻³–10⁻² mbar: a diffusion pump or a large Roots booster backed by a two-stage pump. For production stills (0.5–2 m² evaporator area) the set is typically a diffusion pump of 2,000–8,000 L/s on a DV90 or DV175 backing pump through a cold trap; for smaller stills and where oil back-streaming matters (food and pharma distillate), a two-booster set (MB600 → MB150 → DV60) reaches 5 × 10⁻³ mbar oil-free above the backing pump.

The gas load at the short-path stage is tiny (the feed is degassed; the light ends were removed) and the issue is ultimate pressure and cleanliness: every seal, every gasket, every drop of pump oil that migrates backward raises the pressure and contaminates a product that sells for hundreds of dollars a kilogram. Two-stage oil-sealed backing pumps with cold traps, or dry backing, and ISO-KF/CF connections throughout. A cold trap at −40 to −80 °C between the still and the booster catches the volatiles that do come off and protects the pumps; without it the backing pump oil fills with terpenes in a shift.

Essential-oil, CBD and fragrance operators scaling from laboratory glass short-path kits to production stills consistently under-specify the vacuum: the glass kit ran on a 5 m³/h two-stage pump at 0.01 mbar because the load was a few grams an hour; the 50 kg/h still needs a booster set two orders of magnitude larger to hold the same pressure.

3. Vacuum crystallisation: 20–100 mbar

A vacuum crystalliser cools a hot saturated solution by evaporating part of its own solvent under vacuum — flash cooling — rather than through a heat-exchange surface that would foul with crystals. The solution enters at, say, 80 °C; the vessel is held at 40 mbar (boiling 29 °C); water flashes off, the solution cools toward 29 °C, becomes supersaturated, and crystals grow. Thai plants use it for salt, MSG, citric acid, lysine, sugar (the vacuum pan is a crystalliser) and pharmaceutical intermediates.

The vacuum system is the same as an evaporator's: the flashed vapour — large, 5–15 % of the feed mass — goes to a condenser (barometric or surface, on cooling tower water, so the crystalliser pressure is set by the cooling water temperature as in the sugar mill and dairy evaporator notes), and the pump removes non-condensables: dissolved air from the feed (a lot — the feed is cold-saturated), leakage, and CO₂ from carbonate or citric systems. A liquid ring pump sized on the hot-season condenser condition — LS275-220 or LS410-320 on a multi-stage crystalliser train — or a steam-jet first stage into a liquid ring pump where the last stage is pulled to 15–20 mbar to reach a low final temperature. For a continuous DTB (draft-tube-baffle) crystalliser on MSG at 60 mbar: ~10 Nm³/h of non-condensables, warm condenser → about 900 m³/h at the inlet → an LS275-220 with chilled seal water, or an LT250-200 two-stage. Crystal dust and foam reach the condenser; a knock-out pot and a stainless pump.

4. Protecting the set across the three regimes

Regime Main threat to the pump Protection
Column, 2–50 mbar Solidifying distillate, acid carry-over, methanol Heated inlet line, knock-out pot, stainless liquid ring or heated dry screw inlet, seal-water pH control
Short-path, 10⁻³ mbar Terpenes and light ends in the backing oil; back-streaming Cold trap −40 to −80 °C, foreline trap, dry or two-stage backing, frequent oil change
Crystalliser, 20–100 mbar Crystal dust, foam, warm cooling water Knock-out pot, anti-foam, sub-cooler or chilled seal water, stainless

In all three, the leak rate of the process vessel is the design load. A pressure-rise test on the isolated system (< 0.5 mbar/min for a column, < 0.01 mbar/min for a short-path still) at commissioning and after every maintenance shutdown is the cheapest vacuum improvement available.

Recommended Dr.Vakuum machines

Roots boosters (MB Series) — the inlet stage for columns at 1–10 mbar and the stages of oil-free short-path sets: MB150, MB300, MB600, MB1200.

Two-stage liquid ring (LT Series) — backing columns, carry-over tolerant: LT200-120, LT230-160V, LT250-200.

Dry screw (DSI Series) — water-free backing, solvent recovery: DSI150, DSI300.

Two-stage oil-sealed vane (DV Series) — short-path backing, with cold trap: DV60, DV90, DV175.

Single-stage liquid ring (LS Series) — crystallisers and column condensers: LS275-220, LS410-320.

How the booster multiplies a backing pump's speed in exactly these bands, and how to stage it, is in When a Roots booster pays.

Process to set. Tell us the pressure the chemistry needs, the top-of-column or still temperature, the leak rate if you have it and what is in the light ends, and we will size the stages and the traps. Talk to an engineer.